MCNConfig Program: Triggered Output Actions Option
121
68-11824-210
5.
Select the Mouse tab at the bottom of the window.
Enter appropriate Mouse function(s)
We have added the ability to reset the alarm relay with
the left mouse button (Set the state to 0).
You could also set up a mouse function to set the alarm
(Set to 1) if you desire.
At this stage, we've set up a standard single-bit Display Table entry.
We'll now add the Output Actions that make a standard Display Table a Triggered Output Type.
6.
Select the Actions tab on the bottom of the
window. This is where we enter the Output
Actions.
A new Display Table starts out with no Output
Actions.
Right-Click on the header row and select
Append from the menu.
7.
Enter an ID number, and a descriptive Name
The Output Actions are very similar to the
Mouse functions. You can Set a bit to a 1 or 0,
Toggle a bit, or ignore a bit.
Select an Action type
(Set, Toggle, or Unused).
Select a bit Value
(1, 0, or Don't Care)
The Set action type sets a bit to either a 1 or 0
as selected in the bit field.