d. Scroll to the LEVEL number. Press and release the setup/enter rotary control.

e. Rotate the setup/enter rotary control clockwise to display available decibel levels.


The audio level changes in real time as the setup/enter rotary control is rotated in the
same way as adjusting the audio with a volume control.

f.

When the desired decibel level appears in the display, press the setup/enter rotary
control to select and save it.

The audio level can be set between -60 dB and 18 dB in 1 dB steps.

To adjust a port’s outgoing audio levels:

a. From the Output Level menu, scroll to the Port number.


When a port number appears onscreen, the port’s label (as set in EHX),
automatically appears next to it.

b. Press and release the setup/enter rotary control.

c. Rotate the setup/enter rotary control clockwise or counterclockwise to display the

available port digits. When the desired port number appears in the display, press and
release the setup/enter rotary control to select it.

d. Rotate the setup/enter rotary control clockwise or counterclockwise to scroll to the

Level number.

e. Press and release the setup/enter rotary control.

f.

Rotate the setup/enter rotary control clockwise or counterclockwise to display
available decibel level values

The audio level changes in real time as the setup/enter rotary control is rotated in the
same way as adjusting the audio with a volume control.

g. When the desired digit appears in the display, press and release the setup/enter

rotary control to select and save it.

The audio level can be set between -60 dB and 18 dB in 1 dB steps.

3. The Identification Tone (Ident Tone) is typically sent to destinations that require a tone or

audio statement during system setup.

To set the audio source for a port as the Identification Tone, scroll to and select the Ident
Tone Enable
checkbox. To turn off the Identification Tone, clear the checkbox.

The Identification Tone continues until either the Enable checkbox is cleared or Clear Tones
is selected in the Audio menu.


Note:

The source of the Identification Tone is selected from the Maintenance menu. See
5.12 Selecting a source of Identification Tone.

4. To exit the menu, scroll to and select Exit, or to adjust another port’s audio level, repeat the

above procedure(s).