4 connecting user panels and interface modules, Connecting user panels and interface modules – Clear-Com HX System Frames User Manual
Page 25
Key to Figure 4 Rear panel connectors
Feature
Description
1
Two IEC AC power input connectors (1 for each power-supply unit).
2
RJ-45 connectors (36). For connecting the Eclipse HX-PiCo to remote user
panels (V-Series and i-Series user panels), interface modules, interface frames
and other intercom devices.
Note:
The last four ports are four-wire only.
3
General Purpose Outputs (GPOs) connector. Male, 25-pin, D-Type
4
General Purpose Inputs (GPIs) connector. Female, 25-pin, D-Type
5
GPI-6/RLY-6 interface module connector (RJ-45). Connector specifically
designed to connect GPI-6 and RLY-6 interface modules.
6
PiCo-Link connector (RJ-45). High capacity link for connecting two Eclipse HX-
PiCo matrices together, forming a non-blocking system of 72 ports.
7
LAN connector (RJ-45). For Ethernet connections.
Table 4: Key to Figure 4: Rear panel connectors
4.4 Connecting user panels and interface modules
An Eclipse HX-PiCo rear panel contains 36 RJ-45 sockets for connecting the matrix to remote
user panels (V-Series and I-Series user panels), interface modules and other intercom devices.
These sockets are often called ports. Each port socket is given a number on the rear-panel for
easy identification.
All ports contain a voice detection mechanism (VOX) that is programmed in EHX software. VOX
detection:
• Allows the panel operator to know when the audio on a particular channel has
exceeded a threshold.
• Is particularly useful for channels that are inactive periodically, so that the panel
operator is visually cued in the software when audio appears on the line.
25
Eclipse HX-PiCo User Guide