GPI-6 interface in an IMF-102 interface module frame

Connecting a GPI-6 interface that is placed in an IMF-102 interface frame is the same as
connecting a GPI-6 interface placed in an IMF-3 interface frame. The only difference is that an
IMF-102 interface frame houses only two interfaces, which are mounted horizontally rather than
vertically in the frame.

Tip:

For more detailed information, see the individual documentation for these interfaces and

frames, and the Eclipse HX Matrix Installation Guide.

EHX configuration

Use the EHX configuration software to associate a relay to a label. For more information, see
your EHX documentation (including EHX Help).

4.5.7 Connecting to another Eclipse HX-PiCo (PiCo-Link)

You can create one non-blocking 64 port Eclipse HX system by connecting two Eclipse HX-
PiCo matrices together, using the PiCo-Link RJ-45 connectors on the matrices.

To make this connection, use a specially constructed screened CAT-5 cable of maximum length
1 meter (3.28 feet). The cable is wired as shown in Table 11: CAT-5 crossover cable pinout.

Cable end 1

Wire color

Cable end 2

Pin 1

White

/

orange

Pin 3

Pin 2

Orange

Pin 6

Pin 3

White

/

green

Pin 1

Pin 4

Blue

Pin 4

Pin 5

White

/

blue

Pin 5

Pin 6

Green

Pin 2

Pin 7

White

/

brown

Pin 7

Table 11: CAT-5 crossover cable pinout


To transfer data between two linked Eclipse HX-PiCo matrices using the PiCo-Link also requires
that the Ethernet ports are connected with either a cross-over shielded CAT-5 cable or a hub or
switch using conventional shielded CAT-5 cable.