4.5.6 Connecting to a GPI/RLY Interface

The RJ-45 connector labeled GPI/RLY Interface connects the Eclipse HX-PiCo matrix to a
GPI-6 or RLY-6 interface card. The GPI-6 provides six general-purpose opto-isolated logic
inputs. The RLY-6 module provides six single-pole, double-throw relay outputs.

Both card types mount in either an IMF-3 interface frame or an IMF-102 interface frame. Up to
ten GPI-6 or RLY-6 modules can be operated at one time from the matrix by daisy-chaining the
cards together. Each card has an IN and an OUT connector for this purpose.

The RLY-6 and GPI-6 interface modules connect to the GPI/RLY interface connector using
shielded CAT-5 cable.

Important note:

If this port is used a ferrite core must be added to the socket end of the cable. A suitable ferrite
core is Würth Electronik part: 74271132. A shielded cable should be used.

Tip:

For more detailed information about connecting matrices to interfaces, see the

Eclipse HX Matrix Installation Guide.

Connecting to a RLY-6 Interface module

The RLY-6 relay interface module connects up to six programmable relays to the matrix so that
each relay is directly controlled from the matrix. Multiple RLY-6 interfaces can be daisy chained
to provide connection of up to 60 relays to the matrix.

RLY-6 interface module in an IMF-3 interface frame

To connect a RLY-6 interface that has been housed in an IMF-3 interface module frame to the
matrix:

1. Connect one end of an RJ-45 cable (eight wires with no reversal) to the GPI/RLY

INTERFACE connector on the back of the matrix.

2. Connect the other end of the RJ-45 cable into the top RJ-45 (CH. A MATRIX) connector

for the RLY-6.

To connect an additional RLY-6 interface module:

1. Connect one end of a short RJ-45 cable into the lower RJ-45 (CH. B MATRIX) for the

first RLY-6.

2. Connect the other end of the short RJ-45 cable into the top RJ-45 (CH. A MATRIX)

connector for the additional RLY-6.

Additional RLY-6 interfaces are added in the same way, using "daisy-chain" wiring. If there are
multiple RLY-6 interfaces, the inputs in the first interface are numbered 1 to 6 for RLY 1; in the
second interface 1 to 6 for RLY 2, etc. RLY interface 0 is the internal Matrix RLY interface.