beautypg.com

Db-25m connector – Clear-Com HX System Frames User Manual

Page 30

background image

shorted to the relevant normally closed pin. When a general-purpose output becomes active,
the short between the common pin and the normally closed pin is broken and a new
connection is made between the common pin and the normally open pin.

Important note:

If the GP-OUT port is used the following filter must be fitted between the PROC-RCC socket
and the cable:

CINCH FA-25PS/1-LF 25W D-type in-line 1000pF filter
(UK supplier: Farnell 111-4108)

A shielded cable should be used.

Figure 7: Pin configuration of the GPO connector (DB-25M)

DB-25M connector

10

1

2

3

4

5

6

7

8

9

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

Normally open

Common

RELAY6

Normally closed

Normally open

Common

RELAY5

Normally closed

Normally closed

Normally open

Common

RELAY7

Common

RELAY8

Normally closed

Normally open

Normally open

Normally closed

Common

RELAY1

Normally closed

Common

RELAY2

Normally closed

Common

RELAY3

Normally closed

Common

RELAY4

Normally open

Normally open

Normally open

Digital ground

30

Eclipse HX-PiCo User Guide

This manual is related to the following products: