Clear-Com HX System Frames User Manual
Page 39
E
#3/6 Normally open
F
#1/4 COM
G
#2/5 Normally closed
H
#2/5 Normally open
I
#3/6 COM
Table 9: Key to Figure 13: RLY-6 DB-9M connector pinout
RLY-6 interface module in an IMF-102 interface frame
Connecting to a RLY-6 interface module in an IMF-102 interface frame is the same as
connecting to a RLY-6 interface module in an IMF-3 interface frame.
The only difference is that an IMF-102 interface frame houses only two interfaces, which are
mounted horizontally rather than vertically in the frame.
Tip:
For more detailed information, see the individual documentation for these interfaces and
frames, and the Eclipse HX Matrix Installation Guide.
EHX configuration
Use the EHX configuration software to associate a relay to a label. For more information, see
your EHX documentation (including EHX Help).
Connecting to a GPI-6 interface module
The GPI-6 input interface module connects up to six programmable inputs to the matrix so that
each input can control a predefined matrix function. Multiple GPI-6 interface modules can be
daisy-chained to provide connection of up to 60 inputs to the matrix. RLY-6 and GPI-6 interface
modules can be mixed together up to the total limit of 60 items.
Five RLY-6 and five GPI-6 modules provide 30 relays and 30 inputs for a total of 60 inputs and
outputs.
Note:
If both GPI-6 and RLY-6 interface modules are use, you must place the GPI-6 interface modules
first in the daisy chain.
39
Eclipse HX-PiCo User Guide