beautypg.com

Ba c* b a c, Ab a, Wiring – GF Signet 8059 External Relay Modules User Manual

Page 3: Dual sensor system single sensor system, 8059 i/o terminals, Input pass-thru, Lsensor #1 s, Lsensor #2 s, Li/o terminals

background image

3

Signet 8059 External relay module

5. Wiring

A + B + C

” 122 m (400 ft.)

B

A

C*

B

A

C

NC C NO
RELAY A

NC C NO
RELAY B

NC C NO
RELAY C

NC C NO
RELAY D

+

S

3

L

-

+

S

3

L

-

OUTPUT 24VDC

+ -

AC INPUT

INPUT

PASS-THRU

L N

COM

32:(5

Signet 3-8059 Relay Module

Test A

Test B

Test C

Test D

Relay A

Relay B

Relay C

Relay D

LISTED
E171559

®

NC C NO
RELAY A

NC C NO
RELAY B

NC C NO
RELAY C

NC C NO
RELAY D

+

S

3

L

-

+

S

3

L

-

OUTPUT 24VDC

+ -

AC INPUT

INPUT

PASS-THRU

L N

COM

32:(5

Signet 3-8059 Relay Module

Test A

Test B

Test C

Test D

Relay A

Relay B

Relay C

Relay D

LISTED
E171559

®

S

3

L

I/O

Terminals

S

3

L Sensor #1

S

3

L Sensor #2

S

3

L

I/O

Terminals

S

3

L Sensor #1

S

3

L Sensor #2

• S

3

L devices may be connected to any available set of I/O terminals, or may be spliced into existing S

3

L device cable.

*Sensor may be connected to host instrument via pass-through S

3

L terminals on the 8059.

Only one wire should be inserted into a terminal. Splice double wires outside the terminal.

• The

TOTAL cable length from all S

3

L devices to the transmitter must not exceed 122 m (400 ft.).

Do not route I/O cables in conduit containing AC power wiring. Electrical noise may interfere with data signal.

Routing cable in grounded metal conduit will help prevent electrical noise and mechanical damage.

The sensor confi guration must be reset before the host instrument will recognize a new S

3

L device.

(see Calibrate menu, “Reset Sensor Confi guration” in the 8250 Level Transmitter manual.)

Dual Sensor system

Single Sensor system

A + B

” 122 m (400 ft.)

B*

A

B

A

NC C NO
RELAY A

NC C NO
RELAY B

NC C NO
RELAY C

NC C NO
RELAY D

+

S

3

L

-

+

S

3

L

-

OUTPUT 24VDC

+ -

AC INPUT

INPUT

PASS-THRU

L N

COM

32:(5

Signet 3-8059 Relay Module

Test A

Test B

Test C

Test D

Relay A

Relay B

Relay C

Relay D

LISTED
E171559

®

NC C NO
RELAY A

NC C NO
RELAY B

NC C NO
RELAY C

NC C NO
RELAY D

+

S

3

L

-

+

S

3

L

-

OUTPUT 24VDC

+ -

AC INPUT

INPUT

PASS-THRU

L N

COM

32:(5

Signet 3-8059 Relay Module

Test A

Test B

Test C

Test D

Relay A

Relay B

Relay C

Relay D

LISTED
E171559

®

S

3

L Sensor

S

3

L Sensor

S

3

L

I/O

Terminals

S

3

L

I/O

Terminals

+

S

3

L

-

+

S

3

L

-

INPUT PASS-THRU

8059 I/O terminals

Sensor Gnd

Sensor IN

Sensor V+

Sensor Gnd

Sensor IN

Sensor V+

Black (Sensor V+)

Red (Sensor IN)

Silver (Sensor Gnd)

S

3

L

Sensor #1

S

3

L

Sensor #2

S

3

L

I/O

Terminals