Signal priorities – Burkert Type 8681 User Manual
Page 74

74
LED - Color Assignments
Blinking patterns
on
oFF
note
250 ms
250 ms
permanent blinking in the fault color:
- Teaching does not occur
or
- Teach-Reset has been performed or
- Bus error
permanent blinking in the color for that position:
Signal from position 3
450 ms
50 ms
Internal Fault (fault color)
50 ms
450 ms
Service mode / manual control active
(fault color)
125 ms
125 ms
Signal from the external initiator S4
(like "color for position 3")
1 s
3 s
Signal in fault color (and additionally
color of the corresponding valve position):
Maintenance/service required
16.3. signal priorities
if a valve has several overlapping states, the following priority list applies:
Internal Fault (fault color: 450 ms ON, 50 ms OFF)
1.
Manual operating mode is active, e.g. by magnetic manual control - see chapter
2.
Control (fault color: 50 ms ON, 450 ms OFF)
Maintenance/service prompt (fault color: 1 s ON, 3 s OFF)
3.
Other fault, e.g. position measuring system not taught, bus error or other (see chapter
4.
if position feedback signals overlap, the following logic applies:
ON principle, S4 has the highest priority, descending to S1 (i.e. S4 - S3 - S2 - S1).
s1
s2
s3
s4
fault
priority note / Blinking patterns
active
active
active
active
S4
Blinking in S4 blinking pattern (if S4 has been acti-
vated by DIP) since S3/S4 has priority over S1 and S2
active
active
S4
Blinking in S4 blinking pattern, if S4 has been acti-
vated by DIP
active
active
active
S3
Blinking in S3 blinking pattern since S3/S4 position
has priority over S1 and S2
active active
S2
Position feedback of S2 has priority
english
Control Head Type 8681