23

ElectricalInstallation

terminal

Configu-
ration

external circuit

5

(

BO3)

(+) Aeration
valve (

PCV)

or valve 1
(

2P – T or

3P – T)

MODE = 2P – T

or

3P – T

5

6

NC / NO

valve max. 1 A

MODE = PCV

5

6

NC

valve max. 1 A

6

(–) Aeration
valve (

PCV)

or valve 1
(

2P – T or

3P – T)

7

(

BO4)

(+)
Proportional
valve (

SCV),

bleed valve
(

PCV) or

valve 2
(

3P – T)

MODE = 3P – T

MODE = PCV

MODE = SCV

7

7

7

8

8

8

NC / NO

valve max. 1 A

NO

valvel max. 1 A

NC

valve max. 1,5 A

8

(–)
Proportional
valve (

SCV),

bleed valve
(

PCV) or

valve 2
(

3P – T)

Tab. 9: Configuration of terminal block 1

terminal block 2

terminal Configuration

external circuit

9

GND –
Analog output

9

GND

10

(

AOUT)

(+) Analog output
(process value
or manipulated
variable for valve

10

4 - 20 mA /

0 - 10 V

11

GND – Sensor,
actuating element

11

GND

12

24 V DC sensor
supply or actuating
element

12

24 V DC

13

not used

not used

14

(

AIN2)

(+) External default
of set-point value
/ ratio

4 - 20 mA / 0 - 10 V

14

(21

4 - 20 mA /

0 - 10 V

(source)
A-GND)

15

(+) 5 V DC sensor
supply (max. 20 mA)

15

(1, 11 or 23

5 V DC

GND)

16

RS485_COM

16

RS485_COM

17

RS485_A (+)

17

RS485_A

18

RS485_B (–)

18

RS485_B

Tab. 10: Configuration of terminal block 2

english

Type 8611