Burkert Type 2100 User Manual
Page 7

7
Technical data
00175102
2100 A 25M PTFE VA
Tmed -10°C - +180°C
Flow 1 2
Pilot 4,8-10bar
Pmed 16,0bar
G1" Kv20
W3ZLT
CE
CE identification
Permitted pilot pressure
Permitted medium pressure
Type
Control function (CF)
Orifice of the body /
actuator size
Sealing material
Body material
ID number of
the device
Flow direction
Permitted medium temperature
Date of
manufacture
Main dimensions port connection
Flow capacity in standard production conditions
Fig. 1:
Type label - example
6.4. Operating conditions
Observe permitted ranges on the type label of the device!
6.4.1. Temperature ranges
The angle seat valve is suitable for steam sterilization.
Actuator
size
Actuator
material
Medium
(for PTFE seal)
Environment
1)
ø 50 mm
PPS
-10 – +185 °C
0 – +60 °C
2)
0 – +100 °C
3)
ø 70 mm
ø 90 mm
ø 130 mm
Tab. 1: Temperature ranges
1)
If a pilot valve is used, the max. ambient temperature is +55 °C
2)
Pilot air ports with push-in connector
3)
Pilot air ports with threaded bushing
6.4.2. Pressure ranges
Actuator size
Maximum pilot pressure
4)
ø 50 mm
10 bar
ø 70 mm
ø 90 mm
ø 130 mm
7 bar
Tab. 2: Pressure ranges
4)
For the device version ø 70 / Orifice 50 / MC 13 the max.
permitted pilot pressure is limited to 7 bar.
english
Type 2100