beautypg.com

Burkert Type 2100 User Manual

Page 7

background image

7

Technical data

00175102

2100 A 25M PTFE VA

Tmed -10°C - +180°C

Flow 1 2

Pilot 4,8-10bar

Pmed 16,0bar

G1" Kv20

W3ZLT

CE

CE identification

Permitted pilot pressure

Permitted medium pressure

Type

Control function (CF)

Orifice of the body /
actuator size

Sealing material

Body material

ID number of
the device

Flow direction

Permitted medium temperature

Date of
manufacture

Main dimensions port connection

Flow capacity in standard production conditions

Fig. 1:

Type label - example

6.4. Operating conditions

Observe permitted ranges on the type label of the device!

6.4.1. Temperature ranges

The angle seat valve is suitable for steam sterilization.

Actuator
size

Actuator
material

Medium
(for PTFE seal)

Environment

1)

ø 50 mm

PPS

-10 – +185 °C

0 – +60 °C

2)

0 – +100 °C

3)

ø 70 mm
ø 90 mm
ø 130 mm

Tab. 1: Temperature ranges

1)

If a pilot valve is used, the max. ambient temperature is +55 °C

2)

Pilot air ports with push-in connector

3)

Pilot air ports with threaded bushing

6.4.2. Pressure ranges

Actuator size

Maximum pilot pressure

4)

ø 50 mm

10 bar

ø 70 mm
ø 90 mm
ø 130 mm

7 bar

Tab. 2: Pressure ranges

4)

For the device version ø 70 / Orifice 50 / MC 13 the max.
permitted pilot pressure is limited to 7 bar.

english

Type 2100