beautypg.com

Edid minder, Using preset mode – Extron Electronics PoleVault IP Systems PVS 305SA IP User Manual

Page 46

background image

EDID Minder

The PVT RGB D IP Plus (EDID) and the PVT RGB D (EDID) incorporates EDID Minder, which
allows the transmitter to communicate the appropriate EDID information to the source, ensuring
correct video output resolution.
The 5-pole EDID Minder settings DIP switch is located on the rear of the wallplate.
Once installed, these switch settings are only accessible by removing the device from its
installed location.

The factory EDID setting (default) is 1024x768@60 Hz (preset 2).
The EDID Minder has two modes; a Preset (Emulation) mode and a Learn mode.

Preset Mode is available on all PVT RGB (EDID) models, and allows selection of
pre-programed EDID rates, as shown in the table below.

Learn Mode is available only on the PVT RGB D Plus model, and enables the
displays specific EDID information to be recorded and emulated by the input wallplate.

To use the EDID Minder mode in Preset or Learn Mode, follow the instructions below

Using Preset Mode

1. If already installed, disconnect any sources and displays from the front panel and remove

the wallplate from the wall.

2. On the rear panel, set DIP switch 1 to 50 or 60 kHz as desired.
3. Set DIP switches 2 through 5 accordingly to match the desired EDID rate

(see the table below).

4. Connect the video source to the Computer In VGA connector

and a local display device to the Monitor Out port.

5. Restart the video source and display devices. Verify the image, making

any changes to the EDID settings as needed.

6. When the image is correct, re-install the wallplate.

Preset

Number

Switch setting

Resolution

2

3

4

5

0

OFF

OFF

OFF

OFF

Learn Mode (PVT RGB D Plus only)

1

OFF

OFF

OFF

ON

800x600

2

OFF

OFF

ON

OFF

1024x768 (default)

3

OFF

OFF

ON

ON

1280x720

4

OFF

ON

OFF

OFF

1280x768

5

OFF

ON

OFF

ON

1280x800

6

OFF

ON

ON

OFF

1280x1024

7

OFF

ON

ON

ON

1360x768

8

ON

OFF

OFF

OFF

1366x768

9

ON

OFF

OFF

ON

1400x1050

A

ON

OFF

ON

OFF

1440x900

B

ON

OFF

ON

ON

1600x1200

C

ON

ON

OFF

OFF

1680x1050

D

ON

ON

OFF

ON

1920x1080

E

ON

ON

ON

OFF

1920x1200

F

ON

ON

ON

ON

N/A

EDID

Selection

60

Hz

50

1 2 3 4

ON

5

NOTE This setting is for

1024x768@60 Hz,

preset 2 (factory default)

COMPUTER IN

AUDIO

IN

OUT

MONITOR OUT

IR OUT

S G

PVT RGB D Plus

G R L

RGB A

OUT

RGB B

OUT

G S

12

3
4

ON

5

EDID
Switch

PoleVault IP Systems • Installation — Stage 5 (Configuration)