MLA-VC10 • Installation and Setup

2-5

Measuring voltage for a

Biamp Precedence CMA 60 amplifier

Several Biamp amplifiers have

three screw terminals labeled

"remote level". In the picture

at right, the control voltage is

indicated by a C on the panel

over the corresponding screw

terminal. The ground terminal is indicated with a and the

reference terminal is indicated by a +10v.
Even if the voltage is indicated, use a voltmeter to measure the

voltage between the control terminal and the ground terminal

as shown in figure 2-5. Write down the measured voltage and

which terminal is ground as this will be important when you set

the DIP switches.

Figure 2-5 — Measuring control voltage for a Biamp
Precedence CMA 60

N

For three-terminal amplifiers, always connect the

MLA-VC10 to the control voltage terminal and ground

terminal of the amplifier's control port. Leave the other

terminal (+10v in this example) open (not connected).

N

The MLA-VC10 provides a control voltage (supply

voltage) of 0 to 10 VDC. The MLA-VC10 can control

amplifers that use a higher control voltage. However, in

this situation, the maximum volume may not be reached.