beautypg.com

Reference information, Specifications – Extron Electronics FPC 5500 User Manual

Page 57

background image

Extron FPC 5500 • Specifications

51

Reference

Information

Specifications

Control connection to matrix

Connectors .................................... 1 RJ-45 female connector
Data rate ........................................ 10/100Base-T, half/full duplex with autodetect
Default settings .............................. Link speed and duplex = autodetect

IP address = 192.168.254.253
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off

Program control ............................. Extron FPC 5500 software


General

Power supply .................................. External

Input: 100-240 VAC, 50-60 Hz
Output: 12 VDC, 3 A, 36 watts

Power consumption

Device ..................................... 28 watts, 12 VDC
Device and power supply ......... 31 watts, 100-240 VAC, 50-60 Hz

Temperature/humidity .................... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

Operating: +14 to +131 °F (-10 to +55 °C) / 10% to 90%, noncondensing

Cooling .......................................... Convection, no vents
Thermal dissipation

Device ..................................... 94.7 BTU/hr
Device and power supply ......... 105 BTU/hr

Mounting

Rack mount ............................. Yes

Enclosure type ................................ Metal
Enclosure dimensions

FPC 5500 ................................. 12.2” H x 19.0” W x 2.8” D

(31.0 cm H x 48.3 cm W x 7.2 cm D)

Product weight

FPC 5500 ................................. 13.9 lbs (6.3 kg)

Shipping weight ............................. 20.0 lbs
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance

Safety ...................................... CE
EMI/EMC ................................. CE**, C-tick, FCC Class A**, ICES, VCCI
Environmental .......................... Complies with the appropriate requirements of RoHS, WEEE

NOTE:

**CE and FCC testing is conducted with STP (shielded twisted pair) cable.

MTBF ............................................. 30,000 hours
Warranty ........................................ 3 years parts and labor

NOTE: All nominal levels are at ±10%.