Extron Electronics FOX Matrix 14400 User Guide User Manual
Page 51
If desired, adjust any of these values as follows:
1.
Click in the desired field. The field changes to an editable field appropriate to the value
being changed and the graphic cursor becomes a text cursor.
•
The
Date
field becomes a set date field, with the date in the
format (M)M/(D)D/YYYY. Leading zeroes are not shown.
•
The
Time (local)
field becomes a set time field, with the
time in the format HH:MM:SS (00:00:00 to 23:59:59).
•
The
GMT
field becomes a set offset field, with the offset in the format
±HH:MM (–12:00 to +14:00).
2.
Edit the field as desired to set the proper value. For time, remember to use 24-hour
time. Leading zeroes are optional.
3.
Press the
4.
Click the
Take
button to make the date change take affect.
Sync Time to PC button
Clicking the
Sync Time to PC
button causes the computer you are operating to send its
internal time to the switcher in a set time command.
Use Daylight Savings check box
To turn Daylight Saving Time on and off for North America, select the
Use Daylight Saving
checkbox. When Daylight Saving Time is turned on, the switcher automatically updates its
internal clock between Standard Time and Daylight Saving Time in the spring and fall on the
date that the time change occurs in the country or region selected. When Daylight Saving
Time is turned off, the switcher does not adjust its time reference.
NOTE: For Daylight Saving Time in Europe and Brazil, see the
Administrator Password and User Password fields
The
Administrator Password
field displays the password required to log on to the matrix
switcher via the Ethernet port with all of the rights and privileges of an administrator. The
User Password
field displays the password required to log on to the matrix switcher via
the Ethernet port as a user, without all of the rights and privileges of an administrator.
Passwords are case sensitive and are limited to 12 upper-case and lower-case
alphanumeric characters.
Both password fields are masked with asterisks (
************
) as a security measure.
NOTES:
•
Editing the
Administrator
Password
field while connected via the Ethernet port
can immediately disconnect the user from the switcher. Extron recommends editing
this field using one of the serial ports and protecting the Ethernet access to this
screen by assigning an administrator password to qualified and knowledgeable
personnel only.
•
An administrator password must be created before a user password can be
created.
•
The HTML language reserves certain characters for specific functions (see
FOX Matrix 320x and FOX Matrix 14400 • Matrix Software
45