Command and Response Table for SIS Commands (continued)

Command

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Information requests (continued)

NOTE: There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is the

overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware
update, which is available at

www.extron.com

.

Query firmware version

Q

X2$]

Example:

Q

1.23

]

The factory-installed controller firmware version
is 1.23 (sample value only).

Query controller firmware
version (verbose)

0Q

X2$

-

X2%

-

X2%]

Provide a detailed status of the Ethernet protocol
firmware, the controller firmware, and any
firmware upgrade. An asterisk (*) marks the
firmware that is running. A caret (^) marks that
the firmware has a bad checksum or an invalid
load. ?.?? marks that firmware is not loaded.

Response description:

Ethernet protocol firmware version-controller firmware version-updated firmware version

]

Example:

0q

Ethernet protocol

firmware

Description

FOX Matrix firmware version

Updated firmware version

* indicates the version running

Upload date and time

1.23-1.00(1.68-FOMX Series -Wed, 20 Feb 2008 00:00:00 GMT)-1.00*(1.06-FOMX Series -Mon, 17 Mar 2007 16:39:21 GMT)

Request system status

S

FOX Matrix 320x

X2^

X2^

X2^

X2^

X2^

X2^

X2^

X2^

X2^

X2&

X2*

X2*

X2*

X2*

X2*

X2*

X2*

X2*

X2(

X2(

X2(

X2(]

FOX Matrix 14400

X2^

X2^

X2^

X2^

X2^

X2^

X2^

X2&

X2*

X2*

X2*

X2*]

Response description (

FOX Matrix 320x):

+3.3V•+5V•+2.5V•+1.8V•+12V (backplane) •+12V (primary PS1)•+12V (redundant PS1)•+12V (Primary PS2)•+12V (redundant PS2)•Temp•

Fan1 RPM•Fan2•Fan3•Fan4•Fan5•Fan6•Fan7•Fan8•Pri1 PS status•Red1 PS status•Pri2 PS status•Red2 PS status

]

Response description (

FOX Matrix 14400):

+3.3V•+5V•+1.3V•+1.2V•+12V (backplane)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan1 RPM•Fan2•Fan3•Fan4

]

Example
(

FOX Matrix 14400):

S

Backplane receiving 12.00 V

Internal temperature 78.8° F

Fan 1 rotating at 2,909 RPM

3.3 V power system at 3.27 V

3.27•4.95•1.31•1.22•12.00•12.06•12.12•+078.80•02909•02909•02909•02860

NOTE

:

X2$

= Firmware version number to second decimal place (x.xx)

X2%

= Verbose firmware version-description-upload date/time.

See above

X2^

= Voltage

Positive or negative voltage and magnitude

X2&

= Temperature

Degrees Fahrenheit

X2*

= Fan speed (in RPM)

X2(

= Power supply status

1 = Ok

0 = Out of tolerance or failed