E outside of acceptable levels. see the, Request system, Status – Extron Electronics FOX Matrix 14400 User Guide User Manual
Page 37

Command and Response Table for SIS Commands (continued)
Command
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests (continued)
NOTE: There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is the
overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware
update, which is available at
www.extron.com
.
Query firmware version
Q
X2$]
Example:
Q
1.23
]
The factory-installed controller firmware version
is 1.23 (sample value only).
Query controller firmware
version (verbose)
0Q
X2$
-
X2%
-
X2%]
Provide a detailed status of the Ethernet protocol
firmware, the controller firmware, and any
firmware upgrade. An asterisk (*) marks the
firmware that is running. A caret (^) marks that
the firmware has a bad checksum or an invalid
load. ?.?? marks that firmware is not loaded.
Response description:
Ethernet protocol firmware version-controller firmware version-updated firmware version
]
Example:
0q
Ethernet protocol
firmware
Description
FOX Matrix firmware version
Updated firmware version
* indicates the version running
Upload date and time
1.23-1.00(1.68-FOMX Series -Wed, 20 Feb 2008 00:00:00 GMT)-1.00*(1.06-FOMX Series -Mon, 17 Mar 2007 16:39:21 GMT)
Request system status
S
FOX Matrix 320x
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2&
•
X2*
•
X2*
•
X2*
•
X2*
•
X2*
•
X2*
•
X2*
•
X2*
•
X2(
•
X2(
•
X2(
•
X2(]
FOX Matrix 14400
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2^
•
X2&
•
X2*
•
X2*
•
X2*
•
X2*]
Response description (
FOX Matrix 320x):
+3.3V•+5V•+2.5V•+1.8V•+12V (backplane) •+12V (primary PS1)•+12V (redundant PS1)•+12V (Primary PS2)•+12V (redundant PS2)•Temp•
Fan1 RPM•Fan2•Fan3•Fan4•Fan5•Fan6•Fan7•Fan8•Pri1 PS status•Red1 PS status•Pri2 PS status•Red2 PS status
]
Response description (
FOX Matrix 14400):
+3.3V•+5V•+1.3V•+1.2V•+12V (backplane)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan1 RPM•Fan2•Fan3•Fan4
]
Example
(
FOX Matrix 14400):
S
Backplane receiving 12.00 V
Internal temperature 78.8° F
Fan 1 rotating at 2,909 RPM
3.3 V power system at 3.27 V
3.27•4.95•1.31•1.22•12.00•12.06•12.12•+078.80•02909•02909•02909•02860
NOTE
:
X2$
= Firmware version number to second decimal place (x.xx)
X2%
= Verbose firmware version-description-upload date/time.
See above
X2^
= Voltage
Positive or negative voltage and magnitude
X2&
= Temperature
Degrees Fahrenheit
X2*
= Fan speed (in RPM)
X2(
= Power supply status
1 = Ok
0 = Out of tolerance or failed
FOX Matrix 320x and FOX Matrix 14400 • Programming Guide
31