beautypg.com

Serial ports parameters, Sis command, Configure port timeout – Extron Electronics FOX Matrix 14400 User Guide User Manual

Page 40: Session must be in verbose mode 1 or 3 (see the, Verbose mode

background image

Command

ASCII Command

(host to unit)

Response

(unit to host)

Additional description

IP setup commands (continued)

Set e-mail events for recipient

EX5#X5!

,

X5$

,

X5%

,0EM

}

Ipe

X5#X5!

*

X5$

*

X5%

*0

]

You must first have set an e-mail
recipient for the

X5!

variable, using

the separate

Set e-mail recipient

(CR) command on the previous page.

Example:

E

I69,63,3,0EM

}

IpeI69*63*3*0

]

E-mail account #69 (recipient #5,
JSmith), will receive fail/missing and
fixed/restored messages for input 63.

Read e-mail notifications for one
account (recipient)

EX5#X5!

,

X5$

EM

}

X5%X5%X5%

...

X5%

*0

]

Set DHCP on or off

EX5^

DH

}

Idh

X5^]

X5^

: 0 = off, 1 = on

Read DHCP on/off status

E

DH

}

X5^]

Set serial port parameters

EX5&

*

X5*

,

X5(

,

X6)

,

X6!

CP

}

Cpn

X5&

•Ccp

X5*

,

X5(

,

X6)

,

X6!]

Read serial port parameters

EX5&

CP

}

X5*

,

X5(

,

X6)

,

X6!]

Set serial port mode

EX5&

*

X6@

CY

}

Cpn

X5&

•Cty

X6@]

X6@

: 0 = RS-232, 1 = RS-422,

Read serial port mode

EX5&

CY

}

X6@]

Set verbose mode

EX6#

CV

}

Vrb

X6#]

Read verbose mode

E

CV

}

X6#]

Configure current port timeout

E

0*

X6$

TC

}

Pti0*

X6$]

View current port timeout

E

0TC

}

X6$]

Configure global IP port timeout

E

1*

X6$

TC

}

Pti1*

X6$]

View global IP port timeout

E

1TC

}

X6$]

SNMP setup commands

NOTE: See

SNMP Settings Page

, on page 68. This HTML page provides introductory information about Simple Network Management

Protocol (SNMP) and is the preferred method for performing the functions listed below.

Port mapping

Map SNMP port

E

A

X6%

PMAP

}

PmapA

X6%]

Assign a specific port.

Default:161.

Reset SNMP port to default

E

A161PMAP

}

PmapA00161

]

Disable SNMP port

E

A0PMAP

}

PmapA00000

]

Assign no port for SNMP.
Assign a valid port to enable.

View current SNMP port

E

APMAP

}

X6%]

Unit contact name and location

NOTE: No contact or location (as opposed to

Not•Specified, the default value) is not a valid entry.

Set unit contact info

E

C

X6^

SNMP

}

SnmpC*

X6^]

Set contact info to

X6^

.

Reset unit contact info to default

E

C•SNMP

}

SnmpC*Not•Specified

]

View unit contact info

E

CSNMP

}

X6^]

Set unit location info

E

L

X6^

SNMP

}

SnmpL*

X6^]

Set location info to

X6^

.

Reset unit location info to default

E

L•SNMP

}

SnmpL*Not•Specified

]

View unit location info

E

LSNMP

}

X6^]

Community names

Set unit read-only community name

E

P

X6&

SNMP

}

SnmpP*

X6&]

Set read-only (public) name to

X6&

.

Reset read-only community name
to default

E

P•SNMP

}

SnmpP*public

]

View unit read-only name

E

PSNMP

}

X6&]

Set unit read-write community name

E

X

X6&

SNMP

}

SnmpX*

X6&]

Set read-write (private) name to

X6&

.

Reset read-write community name
to default

E

X•SNMP

}

SnmpX*private

]

View unit read-write name

E

XSNMP

}

X6&]

Access enable

Enable SNMP access and traps

E

E1SNMP

}

SnmpE*1

]

Disable SNMP access and traps

E

E0SNMP

}

SnmpE*0

]

Default is disabled.

View SNMP access setting

E

ESNMP

}

X5^]

Command and Response Table for IP- and SNMP-Specific SIS Commands (continued)

FOX Matrix 320x and FOX Matrix 14400 • Programming Guide

34

This manual is related to the following products: