Command and Response Table for SIS Commands (continued)

Command

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Names

NOTES:

The HTML language reserves certain characters for specific functions (see

Special Characters

on page 35).

Do not use leading spaces in preset names.

If a preset is unassigned, the

X1)

displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset•

X&

.

If a room preset is saved, but not yet named, the default name is Rm

X*

•Prst

X(

.

Write global preset name

EX&

,

X(

NG

}

Nmg

X&

,

X(]

Example:

E

1,Security 1NG

}

Nmg001,Security 1

]

Name global preset 1 “Security 1.”

Read global preset name

EX&

NG

}

X(]

Example:

E

2NG

}

Security 2

]

Global preset 2 is named “Security 2.”

Write room preset name

EX*

*

X1)

,

X(

NP

}

Nmp

X*

*

X1)

,

X(]

Example:

E

1*3,Podium_DVDNP

}

Nmp01*3,Podium_DVD

]

Name room1, preset 3 “Podium_DVD.”

Read room preset name

EX*

*

X1)

NP

}

X(]

Write input name

EX1@

,

X(

NI

}

Nmi

X1@

,

X(]

Example:

E

1,Podium camNI

}

Nmi001,Podium cam

]

Name input 1 “Podium cam.”

Read input name

EX1@

NI

}

X(]

Write output name

EX@

,

X(

NO

}

Nmo

X@

,

X(]

Example:

E

1,Main PJ1NO

}

Nmo001,Main PJ1

]

Name output 1 “Main PJ1.”

Read output name

EX@

NO

}

X(]

Resets

Reset global presets and
names

E

ZG

}

Zpg

]

Clear all global presets and their names.

Reset

one global preset

EX&

ZG

}

Zpg

X&]

Clear global preset

X&

.

Reset all mutes

E

ZZ

}

Zpz

]

Unmute all outputs.

Reset room map

E

ZR

}

Zpr

]

Clear all room definitions.

Reset individual room

EX*

ZR

}

Zpr

X*]

Delete room

X*

.

Reset all room presets

E

ZP

}

Zpp

]

Clear all room presets and names.

Reset individual room preset

EX*

*

X1)

ZP

}

Zpp

X*

*

X1)]

Clear an individual room preset and name.

Reset whole switcher

E

ZXXX

}

Zpx

]

Clear all ties and presets.

Absolute reset

E

ZQQQ

}

Zpq

]

Similar to

Reset whole switcher, plus clear

the IP address to 192.168.254.254 and subnet
mask to 255.255.000.000.

Reset all device settings

E

ZY

}

Zpy

]

NOTE

:

X@

= Output number

01 – (maximum number of outputs for your configuration)

X&

= Global preset #

001 – 064

X*

= Room # (for room presets)

01 – 10 (each can have up to 10 presets (

X1)

s) assigned)

X(

= Name

11 characters maximum for room names

12 characters maximum for all other names

X1)

= Room preset #

00 – 10 (0 = current configuration for room)

X1@

= Input number (for other than tie)

01 – (maximum number of inputs for your configuration)

FOX Matrix 320x and FOX Matrix 14400 • Programming Guide

29

This manual is related to the following products: