As the, Zqqq – Extron Electronics FOX Matrix 14400 User Guide User Manual
Page 35

Command and Response Table for SIS Commands (continued)
Command
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Names
NOTES:
•
The HTML language reserves certain characters for specific functions (see
on page 35).
•
Do not use leading spaces in preset names.
•
If a preset is unassigned, the
X1)
displays [unassigned].
•
If a global preset is saved, but not yet named, the default name is Preset•
X&
.
•
If a room preset is saved, but not yet named, the default name is Rm
X*
•Prst
X(
.
Write global preset name
EX&
,
X(
NG
}
Nmg
X&
,
X(]
Example:
E
1,Security 1NG
}
Nmg001,Security 1
]
Name global preset 1 “Security 1.”
Read global preset name
EX&
NG
}
X(]
Example:
E
2NG
}
Security 2
]
Global preset 2 is named “Security 2.”
Write room preset name
EX*
*
X1)
,
X(
NP
}
Nmp
X*
*
X1)
,
X(]
Example:
E
1*3,Podium_DVDNP
}
Nmp01*3,Podium_DVD
]
Name room1, preset 3 “Podium_DVD.”
Read room preset name
EX*
*
X1)
NP
}
X(]
Write input name
EX1@
,
X(
NI
}
Nmi
X1@
,
X(]
Example:
E
1,Podium camNI
}
Nmi001,Podium cam
]
Name input 1 “Podium cam.”
Read input name
EX1@
NI
}
X(]
Write output name
EX@
,
X(
NO
}
Nmo
X@
,
X(]
Example:
E
1,Main PJ1NO
}
Nmo001,Main PJ1
]
Name output 1 “Main PJ1.”
Read output name
EX@
NO
}
X(]
Resets
Reset global presets and
names
E
ZG
}
Zpg
]
Clear all global presets and their names.
Reset
one global preset
EX&
ZG
}
Zpg
X&]
Clear global preset
X&
.
Reset all mutes
E
ZZ
}
Zpz
]
Unmute all outputs.
Reset room map
E
ZR
}
Zpr
]
Clear all room definitions.
Reset individual room
EX*
ZR
}
Zpr
X*]
Delete room
X*
.
Reset all room presets
E
ZP
}
Zpp
]
Clear all room presets and names.
Reset individual room preset
EX*
*
X1)
ZP
}
Zpp
X*
*
X1)]
Clear an individual room preset and name.
Reset whole switcher
E
ZXXX
}
Zpx
]
Clear all ties and presets.
Absolute reset
E
ZQQQ
}
Zpq
]
Similar to
Reset whole switcher, plus clear
the IP address to 192.168.254.254 and subnet
mask to 255.255.000.000.
Reset all device settings
E
ZY
}
Zpy
]
NOTE
:
X@
= Output number
01 – (maximum number of outputs for your configuration)
X&
= Global preset #
001 – 064
X*
= Room # (for room presets)
01 – 10 (each can have up to 10 presets (
X1)
s) assigned)
X(
= Name
11 characters maximum for room names
12 characters maximum for all other names
X1)
= Room preset #
00 – 10 (0 = current configuration for room)
X1@
= Input number (for other than tie)
01 – (maximum number of inputs for your configuration)
FOX Matrix 320x and FOX Matrix 14400 • Programming Guide
29