Command and Response Table for SIS Commands (continued)

Command

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Save, recall, and directly write presets (continued)

NOTES:

A room can contain a maximum of 16 outputs (

X@

s).

If a room is not defined (does not exist in the switcher), the matrix switcher responds with the error code E11.

An output can belong to only one room.

The maximum number of rooms (

X*

) is 10.

Write room outputs

EX*

,

X@

1

,

X@

2

, ...

X@

n

MR

}

Mpr

X*

,

X@

1

,

X@

2

, ...

X@

n

]

See the notes below.

Example:

E

8,3,04,5,6MR

}

Mpr8,03,04,05,06

]

Outputs 3, 4, 5, and 6 are assigned to room 8.

Read room outputs

EX*

MR

}

X(

,

X@

1

,

X@

2

, ...

X@

n

]

NOTES

:

If no outputs have been assigned to the room, the switcher returns [unassigned]

]

.

The default name (

X(

) is the room number with four trailing spaces: “Room•#

X*

••••”.

Example:

E

3MR

}

Room•#03••••,01,02,08,09

]

Outputs 1, 2, 8, and 9 are assigned to room 3.

Save ties as a room preset

X*

*

X1)

,

Rmm

X*

•Spr

X1)]

Command character is a comma.

NOTE: You must have assigned outputs to a room (

EX*

,MR

}

) before you can save a room preset.

Example:

3*9,

Rmm03•Spr09

]

Save current ties as preset 9 for room 3.

Recall room preset

X*

*

X1)

.

Rmm

X*

•Rpr

X1)]

Command character is a period.

Clear room preset ties

E

+

X*

*

X1)

P0*!

]

Rmm

X*

•Spr

X1)]

Clear all ties in room

X*

preset

X1)

.

Example:

E

3MR

}

Room•#03••••,001,002,008,009

]

Outputs 1, 2, 8, and 9 are assigned to room 3.

Directly write a room preset

E

+

X*

*

X1)

P

X!

*

X@

!

X!

*

X@

%

X!

*

X@

$ ...

X!

*

X@

!

}

Enter as many ties as are valid for this
configuration. The ! tie command, & tie, and %
tie commands are all valid and equivalent.

Rmm

X*

•Spr

X1)]

Example:

+7*3P12*7&11*5&4*5%6*6!

Esc

Brackets are shown to separate ties for clarity
only. Create preset 3 for room 7, which ties
input 12 to output 7, input 11 to output 5,
input 4 to output 5, and input 6 to output 6.

Rmm07•Spr03

]

View ties, mutes, and presets

NOTE: The

& read tie command and % read tie command can be used interchangeably.

View output tie

X@

&

X!]

Example:

15&

27

]

Input 27 is tied to output 15.

View output tie

X@

%

X!]

Example:

7%

02

]

Input 2 is tied to output 7.

View output mutes

E

VM

}

X#

1

X#

2

...

X#

n

]

Each

X#

response is the mute status of an output,

starting from output 1.
n is the highest-numbered installed output.

NOTE: The switcher reports the mute status for all outputs, up to the highest numbered output on the highest numbered slot with an

I/O board installed. The switcher does not recognize gaps in the board installation. For example, if boards are installed in only slots 1
and 3, leaving slot 2 empty, the switcher returns mute status for 48 sequential outputs. The mute status for the outputs in slot 2, inputs
17 through 32, can be ones or zeroes (the switcher allows you to mute an output that is not installed, so long as it is numbered lower
than the highest numbered output installed).

NOTE

:

X!

= Input number

000 – (maximum number of inputs for your configuration) (000 = untied)

X@

= Output number

001 – (maximum number of outputs for your configuration)

X#

= Mute

0 = not muted;

1 = muted

X*

= Room # (for room presets)

01 – 10 (each can have up to 10 presets (

X1)

s) assigned)

X1)

= Room preset #

01 – 10

FOX Matrix 320x and FOX Matrix 14400 • Programming Guide