beautypg.com

Command and response table for sis commands, Command and response table for, Sis commands – Extron Electronics FOX Matrix 14400 User Guide User Manual

Page 30: Symbol definitions

background image

Command and Response Table for SIS Commands

Symbol Definitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D)

|

= Pipe (can be used interchangeably with the

}

character)

= Space character

E

= Escape key (hex 1B)

W

= Can be used interchangeably with the

E

character

X!

= Input number (for tie)

000 – (maximum number of inputs for your configuration) (000 = untied)

X@

= Output number

001 – (maximum number of outputs for your configuration)

X#

= Mute

0 = not muted

1 = muted

X$

= SFP number or reclockable output number

000 – 320 (FOX Matrix 320x) or 144 (FOX Matrix 14400) (000 = global [SFP only])

X%

= Output reclocking rate

00 = auto (default)

01 = bypass

X^

= Laser control

0 = disable

1 = enable

2 = automatic

X&

= Global preset number

00 – 64 (00 = current configuration for view only)

X*

= Room number (for room presets)

10 max. (each can have up to 10 presets (

X1)

) assigned)

NOTE: A room is a subset of operator selected outputs that relate to each other. The FOX matrix switcher supports up to 10 rooms, each of

which can consist of from 1 to 16 outputs.

X(

= Name

12 characters maximum for input names, output names, global preset names, and
room preset names
Upper- and lower-case alphanumeric characters and _ / and spaces are valid.

NOTE: The following characters are invalid or not recommended in the name:

~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X1)

= Room preset #

10 maximum

NOTE: A room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from

memory, it becomes the current configuration.

X1!

= Connection status

0 = no input connected

1 = input connected

X1@

= Input number

001 – 320 (FOX Matrix 320x) or 144 (FOX Matrix 14400)

X1#

= Number (quantity) of inputs

In sets of 16 (016, 032, 048, 064, and so on)

X1$

= Number (quantity) of outputs

In sets of 16 (016, 032, 048, 064, and so on)

X1%

= Board installed

0 = No board installed

4 = Non-pathological multimode board

1 = Non-reclocking multmode board*

5 = Non-pathological singlemode board

2 = Non-reclocking singlemode board*

6 = Pathological singlemode board

3 = 3G, SDI, HD-SDI board

x = Unknown board or mix of transceivers

X1^

= I/O board slot number

01 – 09 or 20

X1&

= Transceiver module installed

0 = No module installed

3 = 3G-SDI, HD-SDI, SD-SDI module

1 = Non-pathological multimode module

4 = Pathological singlemode module

2 = Non-pathological singlemode module

X1*

= Transceiver module number

001 – 320 (or maximum number of transceiver modules for your configuration)

X1(

= Reclocking status

0 = Signal reclocked

1 = Signal not reclocked

X2)

= Vendor/manufacturer name

X2!

= Transmit output power in milliwatts

X2@

= Receive optical power in milliwatts

X2#

= SFP temperature

Degrees Celsius

X2$

= Firmware version number to second decimal place (x.xx)

X2%

= Verbose firmware version-description-upload date and time. See the Query firmware version (verbose) command on

page 31

.

X2^

= Voltage

Positive or negative voltage and magnitude

X2&

= Temperature

Degrees Fahrenheit

X2*

= Fan speed (in RPM)

X2(

= Power supply status

1 = Ok

0 = Out of tolerance or failed

* Legacy board, no longer manufactured, identified for completeness only

FOX Matrix 320x and FOX Matrix 14400 • Programming Guide

24

This manual is related to the following products: