Command and response table for sis commands, Command and response table for, Sis commands – Extron Electronics FOX Matrix 14400 User Guide User Manual
Page 30: Symbol definitions

Command and Response Table for SIS Commands
Symbol Definitions
]
= CR/LF (carriage return/line feed) (hex 0D 0A)
}
= Carriage return (no line feed, hex 0D)
|
= Pipe (can be used interchangeably with the
}
character)
•
= Space character
E
= Escape key (hex 1B)
W
= Can be used interchangeably with the
E
character
X!
= Input number (for tie)
000 – (maximum number of inputs for your configuration) (000 = untied)
X@
= Output number
001 – (maximum number of outputs for your configuration)
X#
= Mute
0 = not muted
1 = muted
X$
= SFP number or reclockable output number
000 – 320 (FOX Matrix 320x) or 144 (FOX Matrix 14400) (000 = global [SFP only])
X%
= Output reclocking rate
00 = auto (default)
01 = bypass
X^
= Laser control
0 = disable
1 = enable
2 = automatic
X&
= Global preset number
00 – 64 (00 = current configuration for view only)
X*
= Room number (for room presets)
10 max. (each can have up to 10 presets (
X1)
) assigned)
NOTE: A room is a subset of operator selected outputs that relate to each other. The FOX matrix switcher supports up to 10 rooms, each of
which can consist of from 1 to 16 outputs.
X(
= Name
12 characters maximum for input names, output names, global preset names, and
room preset names
Upper- and lower-case alphanumeric characters and _ / and spaces are valid.
NOTE: The following characters are invalid or not recommended in the name:
~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X1)
= Room preset #
10 maximum
NOTE: A room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from
memory, it becomes the current configuration.
X1!
= Connection status
0 = no input connected
1 = input connected
X1@
= Input number
001 – 320 (FOX Matrix 320x) or 144 (FOX Matrix 14400)
X1#
= Number (quantity) of inputs
In sets of 16 (016, 032, 048, 064, and so on)
X1$
= Number (quantity) of outputs
In sets of 16 (016, 032, 048, 064, and so on)
X1%
= Board installed
0 = No board installed
4 = Non-pathological multimode board
1 = Non-reclocking multmode board*
5 = Non-pathological singlemode board
2 = Non-reclocking singlemode board*
6 = Pathological singlemode board
3 = 3G, SDI, HD-SDI board
x = Unknown board or mix of transceivers
X1^
= I/O board slot number
01 – 09 or 20
X1&
= Transceiver module installed
0 = No module installed
3 = 3G-SDI, HD-SDI, SD-SDI module
1 = Non-pathological multimode module
4 = Pathological singlemode module
2 = Non-pathological singlemode module
X1*
= Transceiver module number
001 – 320 (or maximum number of transceiver modules for your configuration)
X1(
= Reclocking status
0 = Signal reclocked
1 = Signal not reclocked
X2)
= Vendor/manufacturer name
X2!
= Transmit output power in milliwatts
X2@
= Receive optical power in milliwatts
X2#
= SFP temperature
Degrees Celsius
X2$
= Firmware version number to second decimal place (x.xx)
X2%
= Verbose firmware version-description-upload date and time. See the Query firmware version (verbose) command on
page 31
.
X2^
= Voltage
Positive or negative voltage and magnitude
X2&
= Temperature
Degrees Fahrenheit
X2*
= Fan speed (in RPM)
X2(
= Power supply status
1 = Ok
0 = Out of tolerance or failed
* Legacy board, no longer manufactured, identified for completeness only
FOX Matrix 320x and FOX Matrix 14400 • Programming Guide
24