Dmp 44 lc hardware reset modes, Section for – Extron Electronics DMP 44 LC User Guide User Manual
Page 80
DMP 44 LC Hardware Reset Modes
DMP 44 LC Reset Mode Summary
Mode Mode Activation
Result
Purpose/Notes
Use Factory Firmwar
e
1
Hold the reset button while
applying power.
NOTE: After a mode 1 reset,
update the DMP 44 LC
firmware to the latest
version. DO NOT
operate the firmware
version that results from
this mode reset.
The DMP 44 LC reverts to the
factory default firmware.
Event scripting does not start if the
DMP 44 LC is powered on in this
mode. All user files and settings
(drivers, adjustments, IP settings,
etc.) are maintained.
NOTE: If you do not want to
update the firmware, or
perform a mode 1 reset
by mistake, cycle power
to the DMP 44 LC to
return to the firmware
version running prior to
the reset.
This mode reverts to the
factory default firmware
version if incompatibilty
issues arise with user-
loaded firmware.
NOTE: User-defined
Web pages
may not work
correctly
if using
an earlier
firmware
version.
Reset to
Factory Defaults
5
Press and hold the Reset button for
about 9 sec. until the Power LED
blinks three times (once at 3 sec.,
again at 6 sec., again at 9 sec.),
then release and within 1 second
press Reset momentarily (< 1 sec.).
NOTE: The reset procedure is
aborted if the second
momentary press does
not occur within one
second.
Mode 5 performs a complete
reset to factory defaults, except
for firmware:
• Does everything mode 4 reset
does.
• All mix-points set muted and
set to 0 dB.
• All outputs unmuted and set to
0 dB.
• DSP processing returned to
defaults and bypassed.
• All inputs muted and set to
0 dB.
• All presets and group master
memory cleared.
Useful to start over
with configuration
or uploading, and to
replace events.
DMP 44 LC • Reference Information
74