SENA Rhio10 User Manual
Page 53
53
8-12
A2
0x30: OFF,
0x31: ON (Switch Input),
0x39: Level Mode
“0000”-”1023”:
Level
13
-
Field Separator 0x2C ( “,” )
14-18
A3
0x30: OFF,
0x31: ON (Switch Input),
0x39: Level Mode
“0000”-”1023”:
Level
19
-
Field Separator 0x2C ( “,” )
20-24
A4
0x30: OFF,
0x31: ON (Switch Input),
0x39: Level Mode
“0000”-”1023”:
Level
25
-
Field Separator 0x2C ( “,” )
26-29
I1-I4
0x30: OFF, 0x31: ON
30
-
Field Separator 0x2C ( “,” )
31-34
I5-I8
0x30: OFF, 0x31: ON
35
-
Field Separator 0x2C ( “,” )
Input
State
36-39
I9-I12
0x30: OFF, 0x31: ON
40
-
Field Separator 0x2C ( “,” )
41-44
O1-O4
0x30: OFF, 0x31: ON, 0x32: Wait for a conditional
execution,
0x33: Wait for Delay ON, 0x34: Wait for Delay OFF,
0x35: Run PULSE
45
-
Field Separator 0x2C ( “,” )
46-49
O5-O8
0x30: OFF, 0x31: ON, 0x32: Wait for a conditional
execution,
0x33: Wait for Delay ON, 0x34: Wait for Delay OFF,
0x35: Run PULSE
50
-
Field Separator 0x2C ( “,” )
Output
State
51,52
O9,
O10
0x30: OFF, 0x31: ON, 0x32: Wait for a conditional
execution
0x33: Wait for Delay ON, 0x34: Wait for Delay OFF,
0x35: Run PULSE
-
Indication that the system is standby when conditional execution for output port,
pulse/delay operations are active (with ON command).