2 digital input setting – SENA Rhio10 User Manual
Page 34

34
-
After output control is completed, Rhio10 returns the states of all ports to the host
computer.
4.2 Digital Input Setting
Rhio10 has 12 digital input ports. You can enable/disable each of these digital input ports with
Rhio Manager or by issuing the commands specified in "Ch. 5 I/O Port Related Protocols".
When setting the digital input with Rhio Manager, place your mouse cursor over the Digital Input
LED on the I/O Port Control screen and right-click it to display the Setting window.
4.2.1 Setting Enable/Disable
Figure 4-3 Setting digital input
Digital input setting has two options: Enable and Disable. After selecting either of the options,
press the [Setting] button to apply it in the system. A port cannot be set while it is operating in
Run mode. Therefore, Rhio Manager sends a command that switches its mode to Setting mode
first and then issues the set command when its operation is stopped.
When set to Enable, Rhio Manger receives the ON/OFF state from the device connected to a
digital input port and then displays it. When set to Disable, it displays Disable regardless of the
ON/OFF state of the device connected to the input port.