background image

Setup and Connections

Vlinx MESR321 Modbus Gateway

37

MESR321-xx_R001_2113m

www.bb-elec.com

www.bb-europe.com


b. Click on Internet Protocol (TCP/IP) and click . Change the

parameters to the following:

IP Address = 169.254.102.1

Subnet Mask = 255.255.0.0

Default Gateway = 169.254.102.100

c. Use the Vlinx Modbus Manager Software to search for, discover, and

configure the Modbus Gateway.