TROUBLESHOOTING
Tower Dryer Operations & Service
34
Message
What to do
AUXILIARY STUCK CLOSED TOP WET CONVEYOR
Check Term. 213
CONTACT FAILED TO CLOSE DRY CONVEYOR
Check Term. 209
CONTACT FAILED TO CLOSE AUX. DRY CONVEYOR
Check Term. 210
CONTACT FAILED TO CLOSE DRY LEG
Check Term. 211
CONTACT FAILED TO CLOSE TOP DRY CONVEYOR
Check Term. 212
CONTACT FAILED TO CLOSE AUX. WET CONVEYOR
Check Term. 215
CONTACT FAILED TO CLOSE WET LEG
Check Term. 214
CONTACT FAILED TO CLOSE TOP WET CONVEYOR
Check Term. 213
BINDICATOR ERROR UBS closed while LBS still open
Check Term. 314 & 315
SHUT DOWN OUT OF GRAIN Occurred at ——
DRY SENSOR ERROR MOISTURE SIGNAL OUT OF RANGE
Check the sensor wiring
DRY SENSOR ERROR GRAIN TEMP. SIGNAL OUT OF RANGE
Check the sensor wiring
WET SENSOR ERROR MOISTURE SIGNAL OUT OF RANGE
Check the sensor wiring
WET SENSOR ERROR GRAIN TEMP. SIGNAL OUT OF RANGE
Check the sensor wiring
COLUMN GRAIN RTD SENSOR ERROR RTD OUT OF RANGE
Check the sensor wiring
SHUT DOWN BY MOISTURE CONTROLLER
Try again w/ close supervision
FAILED TO MAINTAIN TO THE TARGET
READY TO START
Press the dryer control START
READY TO START BLOWER
Turn blower switch to ON to start
READY TO START BURNER
Turn burner switch to ON to start
OUT OF GRAIN
Will shut down in ___ seconds
START UNLOAD NOW
Or will shut down ___ seconds
DRYER COOLING OFF Current grain temp. = ____
Blower will shut down in ____ secs/*N:5
or turn the blower switch off to shut down now.
WET PATH NOT ON
Turn load switch to MAN or AUTO to start
FILLING THE DRYER
Please wait...
DRYER IS FULL
Press control STOP button to reset alarm Then press
control START button to restart
EMPTYING THE DRYER
Please wait...
NO POWER TO SLC
Pull E-STOP button out and check Term
100 for 24VDC
START CHECKING Please wait ___ seconds left
TRI-START ON ___ seconds left
STARTING BLOWER 1
STARTING BLOWER 2
STARTING BLOWER 3
STARTING BLOWER 4
PURGING ____ seconds left
OPEN MAIN FUEL VALVES or will shut down in ____ seconds
IGNITION TRIAL ____ seconds left
FIRING VALVE LIMIT SWITCH OPEN OPEN THE FIRING VALVE
Check Term. 112
INTERLOCKED START DRY CONVEYOR FIRST
INTERLOCKED START AUX. DRY CONVEYOR FIRST
INTERLOCKED START DRY LEG FIRST
42