Table C-1 Status messages for both the continuous flow and staged batch modes (cont'd.)
Message
Drying modes
Occurrence
Description
Unloading
Staged batch
Displayed during the unloading
phase
Indicates the time remaining on
the unloading timer
Unloading
Cleanout
Continuous flow,
staged batch
Displayed when the cleanout
delay is active
Indicates the time remaining on
the cleanout delay
Dryer Cooling
Down
Continuous flow,
staged batch
Displayed when the cool-down
timer is active
The dryer is not running, but the
fans are in operation throughout
the duration of the cool-down time
Emergency
Cooling
Continuous flow,
staged batch
Displayed once an emergency
cooling has been initiated, in
response to a grain overheat
shutdown
Indicates the time remaining on
the cool-down timer
Temperature
Hold
Staged batch
Displayed during the drying
phase in either the time or time
and temperature control
scheme, once the drying timer
elapses and the grain tempera-
ture has yet to reach its setpoint
Indicates the difference (in
degrees) between the grain tem-
perature setpoint and the grain’s
actual temperature
98
PNEG-1851 Vision N2