The 2-speed control scheme – Grain Systems PNEG-1851 User Manual
Page 43
Figure 5-2 Speed versus temperature relationship for the 1-speed temperature control scheme
The 2-Speed Control Scheme
In the 2-speed control scheme, you enter the following parameters:
• The low metering roll speed
• The high metering roll speed
• The grain temperature setpoint
As shown in the figure that follows, the metering rolls turn at the high speed setting if the grain temperature
is 1°F (0.56°C) above its setpoint, or they run at the low speed setting if the grain temperature is 1°F (0.56°
C) below its setpoint. The 2-speed temperature control scheme is a precursor to the more comprehensive
5-speed schemes in continuous flow. See
Setting the 2-Speed Temperature Scheme in Continuous Flow,
for details on how to set up this control scheme.
PNEG-1851 Vision N2
43
- PNEG-1890 (16 pages)
- PNEG-595 (26 pages)
- PNEG-1472 (30 pages)
- PNEG-897 (58 pages)
- PNEG-838 (4 pages)
- PNEG-1755 (36 pages)
- PNEG-524 (24 pages)
- PNEG-1080 (2 pages)
- PNEG-728 (47 pages)
- PNEG-673 (57 pages)
- PNEG-1717 (88 pages)
- PNEG-823 (42 pages)
- PNEG-630-6S (23 pages)
- PNEG-1876 (80 pages)
- PNEG-102 (2 pages)
- PNEG-366 (51 pages)
- PNEG-1626 (1 page)
- PNEG-1874 (78 pages)
- PNEG-1798 (34 pages)
- PNEG-1927 (4 pages)
- PNEG-924 (2 pages)
- PNEG-582 (26 pages)
- PNEG-012 (46 pages)
- PNEG-1797 (86 pages)
- PNEG-546 (26 pages)
- PNEG-951 (102 pages)
- PNEG-1650 (92 pages)
- PNEG-1649 (50 pages)
- PNEG-1376 (88 pages)
- PNEG-361 (46 pages)
- PNEG-338 (32 pages)
- PNEG-1276 (78 pages)
- PNEG-1283 (22 pages)
- PNEG-1089 (14 pages)
- QSG-001 (2 pages)
- PNEG-950 (96 pages)
- PNEG-1590 (3 pages)
- PNEG-501 (33 pages)
- PNEG-1447 (68 pages)
- PNEG-707GSI (446 pages)
- PNEG-349 (32 pages)
- PNEG-236 (22 pages)
- PNEG-743 (16 pages)
- PNEG-900 (54 pages)
- PNEG-1935 (92 pages)