VEGACOM 557 Profibus FMS

Setup

FB 210 C:[email protected] LAE=93

Page 2

0076 QANF : KF +20

0078 QLAE : KF +15

007A PAFE : MB 255

007C :

007E :

0080 :

0082 :

0084 :

0086 :

0088 :

008A :

008C :

008E :

0090 :

0092 REC :O M 0.0

0094 :ON M 0.0

0096 :SPA FB 245 — RECEIVE_ALL order ——

0098 Name :RECEIVE

009A SSNR : KY 0,0

009C A-NR : KY 0,0 Order no.=0 –> RECEIVE_ALL

009E ANZW : MW 2

00A0 ZTYP : KC NN

00A2 DBNR : KY 0,0

00A4 ZANF : KF +0

00A6 ZLAE : KF +0

00A8 PAFE : MB 255

00AA :

00AC :

00AE :BE

MW 10 = MW_BLKNO Meas. value block number

FB211: Read in measured value blocks

With this functional component, a measured value block (16 measured values) is read in.

Important information:

The interface number and the order number must be adapted to your application if necessary.
These values relate to the values set in the CP connection planning.

Call:

The functional component must be called up in each program cycle.

:SPA FB 211

Name :R-MW-BLK

BLCK : MW 30

meas. value block number = 1..16

DB : MW 32

data component for file

STAT : MW 50

Status

Status :

0000

= OK

0080 = BLCK Error, unvalid block number

00FF = no reading order given to CP