Db240: basic settings – VEGA VEGACOM 557 Profibus FMS User Manual
Page 33

VEGACOM 557 Profibus FMS
33
Setup
DB240: Basic settings
In this DB, the basic settings and order blocks for CP5431 are determined. Here, only the
Start-target DB (data word 0) may be modified. All other parameters may not be modified.
Start-target DB:
- By this, when using FB210 (read in all measured values) the first data component for saving
the measured values can be stated. Since 16 measured value blocks are read in, 16 data
components must be reserved by the Start-target DB.
DB240 C:[email protected] LAE=40 /64
Blatt 1
—— basic adjustment ——
0: KY = 000,220; Start-target DB (meas. value: DB 220-235)*
1: KY = 000,015; Start-target DB (meas. value: DB 220-235)*
2: KH = 1000; Start Index for 1. meas. value block
3: KY = 000,000; reserved
4: KC =’V-RE’; — READ-corder, Sub Index—
6: KF = +00100; Time out
7: KH = 0000; reserved
8: KC =’DB’; destination, identification
9: KY = 000,220; destination DB
10: KF = +00000; Offset
11: KC =’AR’; Data type Array
12: KF = +00016;
13: KC =’OS’;
14: KF = +00006;
15: KC =’VF’;
16: KY = 003,004; ID=3, Len=4; Index with Subindex
17: KF = +04096; variable Index
18: KY = 000,001; Subindex
19: KY = 000,000; —Read-order without SubIndex—
20: KC =’V-RE’; — Read order without SubIndex —
22: KF = +00100; Time out
23: KH = 0000; reserved
24: KC =’DB’; destination, identification
25: KY = 000,220; destination DB
26: KF = +00000; destination Offset
27: KC =’AR’; Data type Array
28: KF = +00016;
29: KC =’OS’; type of element, Octett-String
30: KF = +00006;
31: KC =’VF’;
32: KY = 002,002; ID=2, Len=2: Index without SubIndex
33: KF = +04096; Index
34: KY = 000,000; ———————————————
35:
* Can be modified.