Receipt of goods and storage, Installation instructions, Mechanical installation – M&C TechGroup MP12 Operator's manual User Manual
Page 9

9
Gas sampling and gas conditioning technology
6-1.1.10-ME
9
RECEIPT OF GOODS AND STORAGE
Please take the sample pump and possible special accessories carefully out of the packaging
material immediately after arrival, and compare the goods with the items listed on the delivery note!
Check the goods for any damage caused during delivery and, if necessary, notify your transport
insurance company without delay of any damage discovered
N O T E !
The equipment should be stored in a protected, frost-free room!
10
INSTALLATION INSTRUCTIONS
When installing the pump make certain that accident prevention regulations and safety instructions
including those for subsequent operation are observed. The safety instructions in section 2.2 must be
observed.
N O T E !
The pump must only be used in the conditions specified in the technical
data.
The pump should be installed away from heat sources and freely ventilated
to prevent any accumulation of heat.
For outdoor installation, the pump must be installed in a housing protected
from frost in the winter and sufficiently ventilated in summer. Exposure to
direct sunlight must be avoided.
N O T E !
Pumps have mechanical moving parts that can induce vibrations. To pre-
vent damages at the pump or at peripheral components / facilities as well
as minimizing noise development an appropriate vibration decoupling is
necessary. For this M&C can deliver e.g. anti-vibration pads.
This explicit is also valid for the connection of the sample lines at the pump
head.
10.1
MECHANICAL INSTALLATION
The mounting dimensions are given in figure 2.
The pump is provided for assembly and therefore it has to be fastened with screws.
Install the pump so that the fan can draw in sufficient cooling air.
Mounting the pump at the highest place in system and/or with pump head downside so that con-
densate can not be assembled inside the head.