You can indirectly control a switcher through the system. If the Transmit Switcher Info
field is checked, Xedio Ingest Server application transmits the switching information over
the Ethernet network to a dedicated software device before starting any recording. This
device will manage the audio and video routing at the switcher with regard to its brand and
protocol, and send an acknowledgement back to Xedio Ingest Server within a determined
delay in order to start the encoder(s).
To set switcher parameters, complete the following fields and then click on the Apply
button.
Field
Description
Transmit Switcher Info
Enables/Disables the use of a software device to
control the switcher(s)
Switcher Config Host IP
IP address of the software device to access to.
Switcher Config Host Port
Port number where to send the switching
information.
Wait For Host Response
TimeOut (in sec.)
Delay for the “acknowledge” coming from the
device.
Note
When timeout delay is reached, Xedio
Ingest Server aborts the recording
process.
The protocol used between Xedio Ingest Server and the "switching device" uses the
following commands:
Commands sent from CleanGest Server to the
switching device
Description
Used before starting a
record
Used at the end of a
record.
The answers received from the device must be as follows: