– Tighten clamping lever 23 again.

– Afterwards, retighten the lock nut of the stop screw 57

again.

In case the angle indicator 25 is not in a line with the 0° mark

of the scale 24 after the adjustment, loosen the screw 56 us-

ing a commercial Phillips screwdriver and align the angle indi-

cator along the 0° mark.

Setting the Standard Bevel Angle 45° (Vertical)
– Bring the power tool into the working position.

– Turn the saw table 30 to the 0° detent 29. The lever 10

must be felt to engage in the detent.

– Turn the stop 19 completely to the rear.

– Loosen clamping lever 23 and tilt the tool arm by handle 4

leftward to the stop (45°).

Checking: (see figure T1)
– Adjust an angle gauge to 45° and position it on the saw ta-

ble 30.

The leg of the angle gauge must be flush with the saw blade 37

over the complete length.
Adjusting: (see figure T2)
– Loosen the lock nut of the stop screw 58 using a commer-

cial box-end or open-end spanner (size 13 mm).

– Screw the stop screw in or out until the leg of the angle

gauge is flush with the saw blade over the complete length.

– Tighten clamping lever 23 again.

– Afterwards, retighten the lock nut of the stop screw 58

again.

In case the angle indicator 25 is not in a line with the 45° mark

of the scale 24, firstly check the 0° setting for the bevel angle

and the angle indicator again. Then repeat the adjustment of

the 45° bevel angle.

Aligning the Scale for Mitre Angles
– Bring the power tool into the working position.

– Turn the saw table 30 to the 0° detent 29. The lever 10

must be felt to engage in the detent.

Checking: (see figure U1)
– Adjust an angle gauge to 90° and position it between the

fence 6 and the saw blade 37 on the saw table 30.

The leg of the angle gauge must be flush with the saw blade 37

over the complete length.
Adjusting: (see figure U2)
– Loosen all four set screws 59 with the Allen key (4 mm) 17

and turn the saw table 30 together with the scale 13 until

the leg of the angle gauge is flush with the saw blade over

the complete length.

– Retighten the screws again.
When the angle indicator 12 is not in line with the 0° mark of

scale 13 after adjusting, loosen screw 60 with a Phillips

screwdriver and align the angle indicator alongside the

0° mark.

Transport (see figure V)

Before transporting the power tool, the following steps must

be carried out:
– Guide the tool arm downward until the transport safety-

lock 20 can be pushed completely inward.

– Slide the saw-table extensions 15 completely in and lock

them in place (by pushing clamping lever 14 down).

– Adjust a 0° bevel angle and tighten clamping lever 23.

– Turn saw table 30 rightward to the stop and tighten locking

knob 9.

– Wind up the mains cable and tie it together with Velcro

strap 61.

– Remove all accessories that cannot be mounted firmly to

the power tool.

If possible, place unused saw blades in an enclosed con-

tainer for transport.

– Carry the machine by the transport handle 44 or hold it by

the recessed handles 16 on the sides of the saw table.

f

The power tool should always be carried by two per-

sons in order to avoid back injuries.

f

When transporting the power tool, use only the trans-

port devices and never use the protective devices.

Maintenance and Service

Maintenance and Cleaning

f

Before any work on the machine itself, pull the mains

plug.

If the machine should fail despite the care taken in manufac-

turing and testing procedures, repair should be carried out by

an after-sales service centre for Bosch power tools.
In all correspondence and spare parts order, please always in-

clude the 10-digit article number given on the type plate of

the machine.
If the replacement of the supply cord is necessary, this has to

be done by Bosch or an authorized Bosch service agent in or-

der to avoid a safety hazard.
Cleaning
For safe and proper working, always keep the power tool and

its ventilation slots clean.
The retracting blade guard must always be able to move freely

and retract automatically. Therefore, always keep the area

around the retracting blade guard clean.
Remove dust and chips after each working procedure by

blowing out with compressed air or with a brush.
Clean the roller 38 regularly.

OBJ_BUCH-1600-002.book Page 36 Monday, August 6, 2012 3:36 PM