2 remote management and nat, 3 system timeout, 2 www screen – ZyXEL Communications P-334WHD User Manual
Page 174: 2 remote management and nat 16.1.3 system timeout, Figure 96 www remote management, Table 73 www remote management

P-334WHD User’s Guide
174
Chapter 16 Remote Management Screens
16.1.2 Remote Management and NAT
When NAT is enabled:
• Use the ZyXEL Device’s WAN IP address when configuring from the WAN.
• Use the ZyXEL Device’s LAN IP address when configuring from the LAN.
16.1.3 System Timeout
There is a default system management idle timeout of five minutes (three hundred seconds).
The ZyXEL Device automatically logs you out if the management session remains idle for
longer than this timeout period. The management session does not time out when a statistics
screen is polling. You can change the timeout period in the System screen
16.2 WWW Screen
To change your ZyXEL Device’s HTTP management settings, click Management > Remote
MGMT to display the WWW screen.
Figure 96 WWW Remote Management
The following table describes the labels in this screen.
Table 73 WWW Remote Management
LABEL
DESCRIPTION
Server Port
You may change the server port number for a service if needed, however you must
use the same port number in order to use that service for remote management.
Server Access
Select the interface(s) through which a computer may access the ZyXEL Device
using this service.
Secured Client IP
Address
A secured client is a “trusted” computer that is allowed to communicate with the
ZyXEL Device using this service.
Select All to allow any computer to access the ZyXEL Device using this service.
Choose Selected to just allow the computer with the IP address that you specify to
access the ZyXEL Device using this service.