beautypg.com

Pa rameters – Yamaha SRCP User Manual

Page 72

background image

5-

14

5

PA

RAMETERS

5-2 Parameter Description

PRM51: Lead program number

This parameter sets the lead program number.

Default value: 0

n

NOTE

The lead program is the program that has been selected as the execution program by the TPB or POPCOM. (See
"9-4 Switching the Execution Program".)
The lead program can also be selected by executing a communication command "@SWI". It may also be switched
when the program data is loaded into the controller from the memory card.

PRM52: Hold gain

Default value: Depends on the robot.

PRM53: Zone output selection

This parameter is used to select the output destination and output logic when the zone
output function is enabled. The zone output is used to control the signal output when the
robot's current position is within the specified range.
A maximum of 4 zone outputs are available by setting for PRM53. The output logic can
also be changed.
This parameter functions are allocated in bit units.

Input range:

0 to 255

Default value: 0

Function allocation in bit units

Function

Bit

Bit

Selected value

Addition value

15 to 8

0

0

7

0

0

6

1

64

5

0

0

4

0

0

3

0

0

2

1

4

1

1

2

0

0

0

PRM53

64+4+2=70

0

1

2

3

4

5

6

7

8 to 15

Zone 0 output enable setting

Zone 1 output enable setting

Zone 2 output enable setting

Zone 3 output enable setting

Zone 0 output logic setting

Zone 1 output logic setting

Zone 2 output logic setting

Zone 3 output logic setting

Reserved for system use

0: Disabled

1: Enabled

0: Disabled

1: Enabled

0: Disabled

1: Enabled

0: Disabled

1: Enabled

0: Positive logic

1: Negative logic

0: Positive logic

1: Negative logic

0: Positive logic

1: Negative logic

0: Positive logic

1: Negative logic

Selected value

Addition value

0

1

0

2

0

4

0

8

0

16

0

32

0

64

0

128

0

Example: To set zone 1 output to positive logic and zone 2 output to negative logic while enabling

zone 1 output and zone 2 output, make the following settings.
PRM53 should be set to "70" because of 0000000001000110 (binary)=70 (decimal).