4 i/o circuits, 4-1 i/o circuit specifications, I/o interf ace – Yamaha SRCP User Manual

Page 38

background image

3-

10

3

I/O INTERF

ACE

3-4 I/O Circuits

3-4

I/O Circuits

This section provides the SRCP controller I/O circuit specifications and examples of how the I/O
circuits should be connected. Refer to these specifications and diagrams when connecting to external
equipment such as a PLC.

3-4-1 I/O circuit specifications

Input Power

DC24V

±10% (supplied through EXT.CN)

Input Circuit

Excluding emergency stop input circuit

Insulation method:

Photocoupler insulation

Input terminal:

Relay contact or NPN open collector transistor connected between
input terminal and 0V terminal.

Input response:

30ms max.

Input current:

5mA/DC24V

Input sensitivity:

Current on: 3mA min.

Current off: 1mA max.

Emergency stop input circuit

Input terminal:

Relay contact connected between emergency stop inputs 1 and 2
(between EMG1 and EMG2).

Input response:

5ms max.

Input current:

40mA/DC24V

Output Circuit

Insulation method:

Photocoupler insulation between internal circuit and output tran-
sistor

Output terminal:

NPN open collector output of all collective output common termi-
nals (0V side)

Output response:

1ms max.

Max. output current:

50mA/DC24V per output

Residual ON voltage:

1.5V max.

Pulse Output Circuit

Output method:

Line driver (26LS31 or equivalent)

Maximum output current: 20mA