2 connecting the power supply, 2-1 power supply, 2-2 connecting the power supply – Yamaha SRCP User Manual
Page 21: Inst alla tion and connection
2-
3
2
INST
ALLA
TION AND CONNECTION
2-2 Connecting the Power Supply
2-2
Connecting the Power Supply
2-2-1 Power supply
No. of phases
Single-phase
Type and Item
SRCP-05
SRCP-10
SRCP-20
Frequency
50/60Hz
Max. power consumption
400VA or less
Power supply voltage
AC200 to 230V
±10%
Single-phase
50/60Hz
600VA or less
AC200 to 230V
±10%
Single-phase
50/60Hz
1000VA or less
AC200 to 230V
±10%
SRCP-05A
SRCP-10A
SRCP-20A
AC100 to 115/200 to 230V
±10%
AC100 to 115/200 to 230V
±10%
AC100 to 115/200 to 230V
±10%
Single-phase
Single-phase
Single-phase
50/60Hz
50/60Hz
50/60Hz
1000VA or less
400VA or less
600VA or less
c
CAUTION
If the power supply voltage drops below the above range during operation, the alarm circuit will work and return
the SRCP controller to the initial state the same as just after power-on, or stop operation. To avoid this problem,
use a regulated power supply with voltage fluctuations of less than
±10%.
Since the SRCP controller uses a capacitor input type power supply circuit, a large inrush current flows when
the power is turned on. Do not use fast-blow circuit breakers and fuses. For the same reason, avoid turning the
power off and on again repeatedly in intervals of less than 10 seconds. This could harm the main circuit ele-
ments in the SRCP controller.
2-2-2 Connecting the power supply
Connect the power supply to the power terminal block on the front panel of the SRCP controller.
Make correct connections while referring to the printed letters and mark. Misconnections may result
in serious danger such as fire. Securely connect the end of each wire to the terminal so that it will not
come loose.
Fig. 2-1 Power supply connections (SRCP-05, SRCP-10, SRCP-20)
1.
3.
SRCP-10, 20
SRCP-05
2.
L (AC IN)
(Ground)
N (AC IN)
1.
3.
2.
L (AC IN)
(Ground)
N (AC IN)
Do not connect.
L
N
T1
T2
L
NC
NC
N
The SRCP-05A, SRCP-10A and SRCP-20A have different connections to T1 and T2, depending on
the input voltage.
Fig. 2-2 Power supply connections (SRCP-05A, SRCP-10A, SRCP-20A)
1.
Do not connect.
Do not connect.
4.
4.
3.
2.
L (AC IN)
Short T1 and T2
when input voltage
is AC100 to 115V.
(Ground)
N (AC IN)
Leave T1 and T2 open
when input voltage is
AC200 to 230V.
1.
3.
2.
L (AC IN)
(Ground)
N (AC IN)
T1
T2
L
NC
NC
N
T1
T2
L
NC
NC
N
0.75mm
2
or more
(equivalent to AWG18)
AC 100V-115V
AC 200V-230V