beautypg.com

Job parameter modification restrictions, Djde operator information pages – Xerox 721P85530 User Manual

Page 344

background image

SPECIFYING DYNAMIC JOB DESCRIPTOR ENTRIES (DJDES)

8-14

XEROX DOCUPRINT 180 LPS PDL REFERENCE

DJDE operator information pages

The changes to the JDE, specified in the DJDE, are incorporated
when END parameter is encountered. The changes begin on the
next record or page following the last DJDE record.

The specification OPRINFO=YES in the JDE ensures that the DJDE
records are printed and sent to the tray at the next page transition
after an END parameter. The DJDE records are printed on a
separate page from the report data. However, no page formatting
occurs and DJDEs on one long record are truncated at the end of the
physical page boundary. They are printed and delivered to the tray
regardless of the OPRINFO parameter if the DJDE contains an error.
Comments in the DJDE may be used for operator notification or
output routing instructions in conjunction with the OPRINFO
parameter.

In duplex processing, DJDE records are printed as duplex pages with
a blank page on the back (and are counted on the accounting sheet).
If a DJDE is applied at the transition to the back side of a duplex page
and OPRINFO=YES, the DJDEs are printed following the back side
page. A row of asterisks (*****) appears on the DJDE page following
the parameters whose printing is so delayed.

The message:

***MISSING END COMMAND OR MISSING PAGE BOUNDARY

is automatically printed on an OPRINFO page at the end of a report if:

No END parameter is found in the DJDE.

No complete page boundary was found before the end of the
report, that is, at the end of report there were some DJDEs that
had not yet been applied.

Job parameter modification restrictions

To process a DJDE, the system has already been required to
process data up to the recognition and interpretation of the DJDE
itself. This requires that the basic description of the input source must
have been correct prior to the application of the DJDE. Thus, the
description of the input source cannot be changed through DJDE,
either by accident or by intent. The system does not allow these basic
parameters to be changed through the DJDE parameter JDE (as
defined in table 8-4). The JDE specified by JDE=DJDE is referred to
as a selected JDE. The parameters which cannot be changed
through a selected JDE are listed in table 8-8.

Table 8-8.

Parameters which cannot be changed through a
JDE

Command

Parameter(s)

VOLUME

HOST
LABEL
UNPACK

OUTPUT

OFFSET

IDEN

All parameters