Dimensions, Gold cgs gas-fired water boiler – Weil-McLain GOLD CGS 550-110-260/02002 User Manual
Page 58
Part number 550-110-260/0200
58
GOLD
CGs
Gas-Fired Water Boiler
Dimensions
13a
Figure 31
Dimensional drawing
T OP VIEW
19
19
13¹¹ ₁₆
28³⁄₈
1⁵⁄₈
4³⁄₄
4³⁄₄
13¹⁄₄
11¹⁄₈
NOTE 2
NOTE 2
2³⁄₈
2¹⁄₄
3¹⁄₄
W
A
9
12
23¹⁄₄
MODEL
CGi
Pressure/temperature gauge
Supply piping (
)
note 1
Return piping (
)
note 1
Relief valve, ¾" NPT
½" NPT to expansion tank/air vent
3" Diameter vent
3"/3½" Dia. air pipe connection
Gas supply piping
Drain valve
Gas supply entrance (right or left side)
26060
R IGHT SIDE
L EFT SIDE
A LL DIMENSIONS IN INCHES
F RONT
Boiler circulator is shipped loose. Circulator may be
mounted on either boiler supply or return piping.
Circulator flange provided with boiler is same size as
recommended pipe size in
, page 14.
Table 3
Boiler supply and return tappings are both 1¼" NPT.
See
, page 14 for recommended system sup-
ply and return piping sizes.
Table 3
Note 2:
Note 1:
Boiler
model
number
Supply
tapping
(inches NPT)
Return
tapping
(inches NPT)
Gas
connection size
Note 3
(inches NPT)
Gas
manifold size
Note 3
(inches NPT)
“A”
Air inlet
pipe center
(inches)
“W”
Jacket
width
(inches)
CGs-3
1 ¼
1 ¼
½
½
6 ½
13
CGs-4
1 ¼
1 ¼
½
½
8
16
CGs-5
1 ¼
1 ¼
½
½
9 ½
19
CGs-6
1 ¼
1 ¼
½
½
11
22
Note 3: Gas piping from meter to boiler to be sized per local utility requirements.