beautypg.com

Service & maintenance — annual start-up, Inspect, Gold cgs gas-fired water boiler – Weil-McLain GOLD CGS 550-110-260/02002 User Manual

Page 36

background image

Part number 550-110-260/0200

36

GOLD

CGs

Gas-Fired Water Boiler

Service & maintenance —

annual start-up

10b

The boiler should be

inspected and started annually

, at the beginning of the heating season,

only by a qualified

service technician

. In addition, the maintenance and care of the boiler designated in

Table 5

and explained on

the following pages must be performed to assure maximum boiler efficiency and reliability. Failure to service
and maintain the boiler and system could result in equipment failure.

Inspect . . . . . . . . . .

Reported problems

Inspect any problems reported by owner and correct
before proceeding.

Boiler area

1. Verify that boiler area is free of any

combustible

materials

, gasoline and other flammable vapors and

liquids.

2. Verify that boiler area (and air intake) is free of any

of the

contaminants

listed on page 9 of this

manual. If any of these are present in the boiler
intake air vicinity, they must be removed. If they
cannot be removed, install combustion air piping
to the boiler in accordance with the appropriate
venting supplement.

Air openings

1. Verify that combustion and ventilation air openings

to the boiler room and/or building are open and

unobstructed

. Check operation and wiring of

automatic combustion air dampers, if used.

2. Verify that boiler vent discharge and air intake are

clean and free of obstructions

.

Flue gas vent system (and air piping)

1.

Visually inspect entire flue gas venting system

(and air piping, if installed) for blockage,
deterioration or leakage. Repair any joints that show
signs of leakage in accordance with vent
manufacturer’s instructions. When air is ducted to
boiler, verify that air inlet hose is connected and
properly sealed.

Failure to inspect

for the above

conditions and have them repaired
can result in severe personal injury
or death.

Pilot and main burner flames

1. Visually inspect pilot burner and main burner

flames as directed under

Start-up

, section

7

of this

manual.

Water piping

1. Check the boiler interior piping and all system

piping for signs of leaks.

2. Repair any leaks before proceeding.

The boiler contains ceramic fiber and fiberglass materials. Use care when handling these
materials per instructions on

page 60

of this manual. Failure to comply could result in severe

personal injury.