P m 6 – Watlow Electric Integrated Controller User Manual Rev C EZ-ZONE PM User Manual

Page 73

background image

Wa t l o w E Z - Z O N E

®

P M I n t e g r a t e d C o n t r o l l e r

7 1

A p p e n d i x

Controller

P M

6

__ __

__

__

-

__ __

__ __

A

__ __

EZ-ZONE

®

Integrated Controller Models

Universal Sensor Input, configuration communications

TRU-TUNE+

®

Adaptive Tune, red-green 7-segment displays

Package Size

6

1⁄16 DIN

Primary Function

C

PID Controller

R

Ramp and Soak

S

Custom Firmware

Power Supply, Digital Input/Output

1

100 to 240V

Å (ac)

2

100 to 240V

Å (ac) plus 2 digital i/o points

3

12 to 40V

Î (dc) and 20 to 28VÅ (ac)

4

12 to 40V

Î (dc) and 20 to 28VÅ (ac), plus 2 digital i/o points

Output 1 and 2 Hardware Options

Output 1

Output 2

CA

Switched dc/open collector

None

CH

Switched dc/open collector

No-arc 15 A power control

CC

Switched dc/open collector

Switched dc

CJ

Switched dc/open collector

Mechanical relay 5 A, form A

CK

Switched dc/open collector

Solid-state relay 0.5 A, form A

EA

Mechanical relay 5 A, form C

None

EH

Mechanical relay 5 A, form C

No-arc 15 A power control

EC

Mechanical relay 5 A, form C

Switched dc

EJ

Mechanical relay 5 A, form C

Mechanical relay 5 A, form A

EK

Mechanical relay 5 A, form C

Solid-state relay 0.5 A, form A

FA

Universal process

None

FC

Universal process

Switched dc (cannot use variable time base)

FJ

Universal process

Mechanical relay 5 A, form A (cannot use variable time base)

FK

Universal process

Solid-state relay 0.5 A, form A (cannot use variable time base)

AK

None

Solid-state relay 0.5 A, form A

KK

Solid-state relay 0.5 A, form A

Solid-state relay 0.5 A, form A

KH

Solid-state relay 0.5 A, form A

No-arc 15 A power control

Communications Options

All options below include EIA-485 Standard Bus.

A

None

1

EIA 485 Modbus RTU®

With options 2 or 3, order option AA for outputs 3 & 4.

2

Modbus RTU 232/485

3

EtherNet/IP™, Modbus TCP

Auxilliary Control Functions

With Communications Options 2 to 6, option A must be ordered below.

A

None

R

Remote Set point input

T

Current Transformer Input (no Output 3 & 4 Option FA, FC, FJ or FK)

L

Integrated Limit Controller with universal input (outputs 3 & 4 Option CJ, EJ or AJ only)

Output 3 and 4 Hardware Options

With Communications Options 2 or 3, option AA must be ordered below.

Output 3

Output 4

AA

None

None

AJ

None

Mechanical relay 5 A, form A

CA

Switched dc/open collector

None

CC

Switched dc/open collector

Switched dc

CJ

Switched dc/open collector

Mechanical relay 5 A, form A

CK

Switched dc/open collector

Solid-state relay 0.5 A, form A

EA

Mechanical relay 5 A, form C

None

EC

Mechanical relay 5 A, form C

Switched dc

EJ

Mechanical relay 5 A, form C

Mechanical relay 5 A, form A

EK

Mechanical relay 5 A, form C

Solid-state relay 0.5 A, form A

FA

Universal Process

None

FC

Universal Process

Switched dc (cannot use variable time base)

FJ

Universal Process

Mechanical relay 5 A, form A (cannot use variable time base)

FK

Universal Process

Solid-state relay 0.5 A, form A (cannot use variable time base)

AK

None

Solid-state relay 0.5 A, form A

KK

Solid-state relay 0.5 A, form A

Solid-state relay 0.5 A, form A

Future Options

Additional Options

AA

Standard EZ-ZONE

®

face plate

12

Class 1, div. 2 (not available with Integrated Limit Controller or mechanical relay outputs)

Ordering Information for Integrated Controller Models

Note: The model of controller that you have is one of many possible models in the EZ-ZONE

®

PM family of controllers. To view the others, visit

our website (http://www.watlow.com/literature/pti search.cfm) and type EZ-ZONE

®

into the Keyword field.