StorageLibrary Installation and User Guide
83
Power Requirements
Table 23. Power Requirements
Power Requirements
Values
Input Voltage
100 240 VAC
Input Frequency
50 - 60 Hz
Inrush Current (Cold Start)
Less than 15 A, 115 VAC
Less than 30 A, 230 VAC
Power Consumption Average
70 W
Power Consumption Peak*
120 W*
* Maximum peak length, less than 10ms.
Climatic Specifications
Table 24. Temperature Range
Temperature
Operating
Range
+10 C to +35 C
Gradient
10 C/hour
Non-Operating
Range
-30 C to +60 C
Gradient
20 C/hour
Table 25. Humidity Range
Humidity
Operating
Range
20%Rh to 80%Rh
Gradient
10%Rh/hour
Non-Operating
Range
10%Rh to 90%Rh
Gradient
20%Rh /hour
Table 26. Altitude Range
Altitude
Operating
Range
-500 to 10000 ft
Non-Operating
Range
-500 to 40000 ft