Tandberg Data T40 User Manual
Page 60
52
Running the Library
Figure 22. The Release Tool Inserted into the Correct Hole on the Left Lower Magazine
Standby Functionality
On the front panel a standby button is available.
To activate Standby mode, press the button for a minimum of 2 seconds. The StorageLibrary will
enter a standby mode in a controlled manner. The following takes place before the StorageLibrary
goes into standby mode:
1 Finish any StorageLibrary activity.
2 The power to the tape drives are switched off.
3 The display is turned off.
4 No StorageLibrary activity is allowed until the standby button is pressed again.
5 The green LED on the front will blink with short blinks- long intervals.
6 To leave the standby mode, press the standby button for 2 second. The StorageLibrary will then
restart and perform a full inventory.