Information about the Operator Interfaces

Words Commonly Used on the FPI and RMI

Some of the words displayed on the FPI and RMI screens may need an explanation.

Table 4. Commonly Used Words on FPI and RMI

Word

Abbr. in
FPI

Description

Idle

The library is idle.

Drive Empty

__

There is no cartridge in the drive.

Drive Loaded

ld

A cartridge is loaded in the drive.

Drive Idle

ie

A cartridge is loaded and the drive is ready to use it.

Drive Rewinding

rw

The drive is rewinding the tape.

Drive Seeking

sk

The drive is searching for specific data on the tape.

Drive Reading

rd

The drive is reading data for transfer to a host via the SCSI interface.

Drive Writing

wr

The drive is writing data received from a host to the tape.

Drive Erasing

er

The drive is erasing data from parts of or the whole of the tape.

Drive Cleaning

cl

A cleaning tape has been inserted into the drive, and the drive is using
it to clean the relevant mechanical parts.

Drive Loading

ld

A tape has been inserted into the drive. The drive is in the process of
mechanically loading the tape.

Drive Unloading

ul

The drive is in the process of mechanically unloading the tape.

Drive Update
Ready

ur

The drive has completed an internal update.

Drive Updating

ud

The drive is in the process of an internal firmware update.

Drive
Calibrating

ca

A data tape has been inserted and loaded into the drive. The drive is
in the process of measuring its physical properties.

During inventory and in the Maps menu, different symbols are displayed on the FPI to indicate if there
are cartridges present in the magazines, in the drives, and in the robotics, as show in

Table 5.

Cartridge Present Symbols on FPI during Inventory and in the Maps Menu

.

Table 5. Cartridge Present Symbols on FPI during Inventory and in the Maps Menu

Symbol on FPI

Description

__

Drive Present, load status empty

??

Drive present, load status unknown

**

Drive not installed

Symbols for the magazine slots and the robotics

Symbol

Description

Grey box if magazine slot/robotics status is unknown

Filled box if cartridge is present in the magazine slot/the robotics

Empty box if cleaning cartridge is present in the magazine slot

N