background image

75

Valve Common Wire

Valve Common

Terminals

Master Valve or
Pump Start Relay
(0.5 A max.)

Hot Post

6. Connect common wire(s) first. To momentarily operate a valve

for identification and/or functional test, touch it’s control wire

to the 24 VAC Hot Post. When operation has been

confirmed, connect the wire to the preferred station terminal.

Note:

Each field wire connection block provides 12 station outputs

(black) and one common output (green). The lower left connection

block provides one master valve/pump start relay output (blue).

To connect wire, push orange tab in, insert wire, then release. Pull

lightly on wire to confirm retention.

Caution: The controller must not be connected directly to

a pump or other high current-draw equipment. A 24 VAC, 0.5A
(max.) relay must be used to facilitate the connection. Failure
to comply can result in severe controller damage.

!