Select Slope Factor

2.

6 – 8% Grade

• Mild 9 – 12% Grade

Gentle

0 – 5% Grade

None/Slight

• Moderate 13 – 20% Grade

• Steep>20% Grade.

SET SLOPE FACTOR STA 01
None/Slight 0-5% Grade

None/ Slight (0 –5%) grade is selected by default. To select

an alternate Slope Factor, turn the Lower Line knob.

Select Sprinkler Location

• All Parts of Slope (default if Slope Factor is other than None)
• Top of Slope
• Middle of Slope
• Bottom of Slope
.

SPRINKLR LOCATION STA 01
None, No Slope Set

None, No Slope Set is selected by default. To choose an

alternate Sprinkler Location, turn the Lower Line knob

to select one of the following options:

31

9

The SlopeFactor is an important component used in the automatic

watering program calculation to determine the amount of run time and

number of repeat cycles required per watering day.

The Slope Factor options are as follows:

1.

Turn the Upper Line knob to select Set Slope Factor.

1.

2.

Turn the Upper Line knob to select Sprinklr Location.

Note:

To prevent runnoff, selecting any slop factor other than

None/Slight

will result in a decrease in station run time per

cycle and an increase in the watering cycle frequency.

Note:

If a Slope Factor of None/Slight is selected, Sprinkler Location

setting is not enabled.