Set flow meter size 1.00 – Toro 12 User Manual

Page 54

background image

4

8

EDIT EXCLUDED STATIONS
Skip (No Flow Only)

01 02 03 04 05 06 07 08
N N N N N N N N

2. Turn the Lower Line knob to change Skip to Edit.

2. Turn the Lower Line knob to select the actual flow sensor size from

the following options: 1.00”, 1.25”, 1.50”, 2.00”, 3.00”, 4.00” and

Insert Type (sizes < 1” or > 4”).

Set Station Exclusion

The station exlusion feature enables individual stations to be omitted

from the Flow Monitor operations.

3. Turn the Upper Line knob to display the first eight station numbers

in sequence.

1. With the the Function dial in FLOW position, turn the Upper Line

knob right to select Edit Excluded Stations.

SET FLOW METER SIZE
1.00”

Set Flow Meter Size

1. With the the Function dial in FLOW position, turn the Upper Line

knob right to select Set Flow Meter Size

4. By default, no stations are excluded (indicated by N) and station

01 is selected. To exclude the selected station, turn the Lower Line

knob to change N to Y (Yes). To select another station number, turn

the Upper Line knob. Repeat as needed for all station numbers.