Day frequency/depletion adjust – Toro 12 User Manual

Page 51

background image

Turn the Lower Line knob to select Day Frequency/Depletion

adjustment option.

ADJUST DAYS (MAD) STA 01
+05% = More Often (45%)

ADJUST DAYS (MAD) STA 01
0% = No Change (50%)

ADJUST DAYS (MAD) STA 06
Non-Adjustable Mode

1.

Day Frequency/Depletion

ADJUST

4

5

% Adjust by Day Frequency/Maximum Allowable Depletion

Note:

If the selected station number is assigned to a User-defined

station mode, the following display will be shown:

3. Turn the Lower Line knob right to increase or left to decrease

the percent value. Maximum adjustment range is +30% to -30%.

2. Turn the Upper Line knob to select the station number.

Stations assigned to the Automated by WeatherTRAK station mode

can be % adjusted by watering Day Frequency/Maximum Allowable

Depletion. For example, when establishing new turf, total water

application can be increased while decreasing the possibility of

runoff. Day Frequency is adjustable from -30% to +30% in 5%

increments. The equivalent MAD value will be displayed ranging

from 20% to 80% (with 50% being the standard depletion rate).

Note: In the following example, the watering day frequency for

station 1 has been increased by 5%, which decreased the MAD

value to 45%. This change translates to irrigation being permitted

when soil moisture content drops to 45% instead of the standard

50% MAD value.