beautypg.com

Toshiba RAS-B13GKVP-E User Manual

Page 69

background image

– 69 –

Indoor fan starts rotating when power supply is turned on.

(Check output DC voltage of fan motor on P.C. board.)

Measure voltage between 3 (GND : BLACK)

and 5 (V line : YELLOW) of motor connector (CN10)

while indoor fan motor is rotating.

DC 1.0V or more

P.C. board is defective.

6 (Blue)

5 (Yellow)

4 (White)

3 (Black)

2 –

1 (Red)

Motor is defective.

Under DC 1.0V

CN10

Yellow

Black

P.C. board

DC

Replace P.C. board.

Replace motor.

(4) Indoor fan motor automatically starts to rotate by turning on power supply

The IC is built in the indoor fan motor. Therefore the P.C. board is also mounted to inside of the motor.

If the P.C. board is soldered imperfectly or the IC is defective, the fan motor may automatically rotate by turning
on power supply.

1. Remove the front panel. (Remove 2 screws.)

2. Remove the cover of the fan motor lead wires.

3. Check DC voltage with CN10 connector while the fan motor is rotating.

NOTE :

• Do not disconnect the connector while the fan motor is rotating.

• Use a thin test rod.