10. INSTALLATION PROCEDURE

10-1. Safety Cautions

1 Installation

plate

Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
installation work.

Make sure the drain hose is
sloped downward.

The auxiliary piping can be
connected at the left, rear left,
rear right, right, bottom right or
bottom left as shown below.

Extension drain hose
(Option: RB-821SW)

6 mm thick heat resisting
polyethylene foam

For the rear left and left piping

Do not allow the drain hose
to become slack.

Cut the piping
hole slightly
sloped

Insulate the refrigerant pipes
separately, not together.

250 mm or more
from wall

In principle,
leave open

When installing the outdoor unit,
leave open in at least two of
directions (A), (B), (C) and (D)
shown in the right figure.

Ensure sufficient space
to allow drainage

(A)

(B)

(C)

(D)

Power cord

Y

Wall

Bottom right

Rear
right

Right

Left

Bottom left

Rear left

As shown in the figure, position power cord and
connecting cable downward, and lead out along
piping connection port.

Before installing the wireless remote controller

• With the remote controller cover
removed, correctly load the
supplied batteries while
observing their polarity.

3 Batteries

Cover

2 Wireless remote controller

2 Wireless
remote

controller

100 mm or more
from wall

4 Remote controller holder

(Mounting holes on both

left and right sides)

8 Remote

controller

holder mounting screw

50 mm or more
from wall

80 mm or more only
when unobstructed to
the front and both sides

Air filters

6 Plasma pure filter

5 Zeolite-plus

filter

140 mm or more

Hook

Hook

Hook

47 mm or more

74 mm
or more

Z Shield pipe
(for

extension

drain

hose)

7 Mounting

screw

200 mm
or more