beautypg.com

Toshiba RAS-B13GKVP-E User Manual

Page 36

background image

– 36 –

Item

11. Temporary

operation

Operation flow and applicable data, etc.

Pressing [RESET] button starts the temporary opera-
tion of [AUTO] operation. When keeping [RESET]
button pressed for 10 seconds or more, the temporary
[COOL] operation is performed.

Description

1) When pressing [RESET] button, the

temporary [AUTO] operation starts.

2) When keeping [RESET] button pressed

for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.

3) When keeping [RESET] button pressed

for 10 seconds or more, “Pi” sound is
heard and the temporary [COOL]
operation starts.

4) If the filter lamp goes on, press [RESET]

button to go off the filter lamp, and then
press [RESET] button again.

5) To stop the temporary operation, press

the button again.

12. Air

purifying
control

This function generates nagative ion while cleaning the air in the room.

If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation,
and if it is received while the air conditioner operates, the air conditioner and the air purifier start
operation.
The air ion generator operates linked with the air purifying operation.

* When the previous operation was the

operation of air conditioner + air purifier,
an operation of air conditioner + air purifier
starts by pushing AC button on the remote
controller.
(Operation of air conditioner + air purifier
is stored in memory.)

*1

Swing is available

*2

Fan speed is Fan Auto mode varies in
order, (M + 1)

(L)

(L–)

(SL).

Filter lamp ON

Press RESET button.

Did you press [RESET] button

for 3 seconds or more?

Did you press [RESET] button

for 10 seconds or more?

Switch to [AUTO RESTART] control.

YES

YES

NO

NO

NO

YES

Temporary [AUTO] operation

Temporary [COOL] Operation

Sending air purifier-ON

Operation lamp ON

Fan ON

Air purifier ON

Air purifying operation

Start of air purifier-ON

Operation lamp OFF

Filter-OFF

Memory position

of louver/COOL

Air conditioner +

air purifier operate

Fan stop

Air purifier-OFF

Louver close

All stop

Air conditioner operates

Sending air purifier-OFF

1

,

2

3

1

2

3

4

,

4

Air conditioner operates

Air conditioner stops

Air purifier operates

Air conditioner +

Air purifier operate

*1

*2

Present status

Stop

Air purifier only

Air conditioner

Joint use of AC and air purifier

Operation button

PURE button

Air conditioner

Air purifier

AC operation*

Stop (All)

AC + Air purifier

AC + Air purifier

All stop

AC operation

All stop

Air purifying operation

AC + Air purifying operation

Louver*1

Cooling position

Follows to AC operation

Fan speed *2

AUTO, L, L+, M, M+, H

Follows to AC operation

This manual is related to the following products: